We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence SJ-M030VC , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Grenada, United Arab Emirates, Romania, Qatar, Spain, Serbia, Dominica, Denmark, South Africa, Zambia, Lesotho, Japan, Nigeria, Slovenia, Mozambique, Mauritania, Ethiopia, Ukraine, Albania, Yemen, Brunei, Guinea-Bissau, Liberia, Ghana, Togo, Barbados, Haiti, Namibia, Austria, Iran, Oman, Egypt, China, Luxembourg, Tunisia, El Salvador, Burundi, Iraq, Mauritius, Belarus, India, Burkina Faso, Cuba, Lebanon.
We have been delivering Keyence units throughout the UK and anywhere in the world for over 10 years. All equipment and parts are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from prominent European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we supply and the professionalism of the FAMAGA employees.
To clarify the value of Keyence SJ-M030VC and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.
Model | SJ-M030VC | |
Type | Head | |
Voltage application method | Pulse AC method | |
Applied voltage | ±5.5 kV | |
Rated output voltage | ±6 kV | |
Ion balance control method | I.C.C. method | |
Static elimination time | ±30 V*1 | |
Ion balance | ||
Air purge supplied pressure | 0.2 MPa max. | |
Control input | Static elimination stop input | Non-voltage input |
Control output | Alarm output | NPN open collector 100 mA (40 V or less) |
Ion level alarm output | ||
Condition alarm output | ||
Effective length | 164 mm | |
Total length | 220 mm | |
Rating | Power voltage | 24 VDC ±10 % |
Current consumption | 450 mA or less | |
Environmental resistance | Ambient temperature | 0 to +40 °C |
Relative humidity | 35 to 65 % RH (No condensation) | |
Weight | Approx. 600 g | |
*1 Please make an inquiry as to the measurement condition. |