We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
GP-M025
Type
Process Sensor
Description
Main Unit, Positive-pressure Type, 2.5 MPa
Stock availability:
On request
If you want to purchase Keyence GP-M025 , along with demand other industrial equipment and replacement parts for its refit, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Slovakia, Singapore, Jamaica, Cameroon, Australia, Fiji, Guyana, Kyrgyzstan, Paraguay, Seychelles, Russia, Gabon, Antigua and Barbuda, Morocco, Guinea-Bissau, Venezuela, Finland, Turkey, Bahrain, Angola, Brunei, Bangladesh, Kiribati, Haiti, Lesotho, Ukraine, Yemen, Congo, Guinea, Kenya, Central African Republic, Uganda, Belize, Peru, Malaysia, Panama, Zambia, Bolivia, Argentina, Myanmar, Comoros, Bulgaria, Sierra Leone, Tonga, Algeria, Cyprus, Kuwait.
We have been delivering Keyence elements all over Britain and anywhere in the planet for over 11 years. All apparatus and parts are provided with appropriate quality certificates, along with a guarantee from the official producer of products Keyence.
Thanks to the direct deliveries from major European manufacturers and a low trade margin, we recommend our customers the most reasonable prices for all products exhibited in our catalogue. If necessary, our certified experts will help you elect industrial instruments that will fully meet the requirements of the production process. More than 4,000 customers have already praised the high quality of the units we deliver and the competence of the FAMAGA workers.
To illuminate the cost of Keyence GP-M025 and delivery terms, you can fill out a special inquiry form on our website, give a list of desirable instruments by E-mail or call to the quoted phone numbers. We will be able to devise the best financial offer for you and prepare optimal delivery times to any urban place in the United Kingdom and any country in the planet.
Model | GP-M025 | |
Rated pressure | -0.1 to +2.5 MPa (-1 to +25 bar) | |
Possible display range | -0.360 to +2.760 MPa (-3.60 to +27.60 bar) | |
Zero-cut pressure value | ±0.5% of F.S. | |
Burst pressure | 35 MPa (350 bar) | |
Display resolution | 0.001 MPa (0.01 bar) | |
Fluid type | Gas or liquid that will not corrode the liquid contact part | |
Type of pressure | Gage pressure | |
Precision | ±1.0% of F.S. or less*1 | |
Repeatability | ±0.3% of F.S. or less*2 | |
Temperature characteristics | ±0.6% of F.S./10°C | |
Connection diameter | G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) | |
Box rotation angle | Maximum 330° | |
Medium temperature | -20 to +100°C (no freezing/condensation)*3 | |
Power supply voltage | 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS | |
Current consumption | 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 | |
Display method | 4 column, digital LED, red/Vertical inversion display possible | |
Operation display light | Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) | |
Hysteresis | During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) During window mode: fixed (0.5% of F.S.) | |
Response | Control output | Selectable from 3 to 5000 ms |
Analogue output | As above + 2 ms (90% response) | |
Output | Output 1 control output | NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable |
Output 2 replacement type | Control output | |
Analogue output | 4-20 mA, maximum load resistance 500 ? (When the electric voltage is more than 20 V)*5 | |
Environmental resistance | Enclosure rating | IP67 |
Pressure resistance | 10 MPa (100 bar) | |
Ambient temperature | -20 to +80 °C (No freezing and no condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes) | |
Shock resistance | IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) | |
Material properties | Port/diaphragm | Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
Other parts | Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass. | |
Applicable cable | M12 connector 4 pin | |
Weight | Approx. 150 g | |
*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C. *2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition. *3 When the temperature of the piping exceeds 80°C, do not connect the cable. *4 Consumption current including output is 0.6 A and under. *5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} ? When 23-30V: R = 622 ? |