Manufacturer
Keyence
Country
Japan
Name
GP-M010
Type
Process Sensor
Description
Main Unit, Positive-pressure Type, 1 MPa
Stock availability:
On request
If you want to purchase Keyence GP-M010 , additionally demand other industrial equipment and spare parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Belarus, Canada, Palestine, Benin, Qatar, Argentina, Pakistan, Cape Verde, Syria, Mauritius, Yemen, Finland, Andorra, Paraguay, Malta, Guyana, China, Burkina Faso, Antigua and Barbuda, Monaco, Belgium, Russia, Dominican Republic, The Gambia, Macedonia, Kenya, Bolivia, Sri Lanka, Czech Republic, Laos, Guinea-Bissau, Bulgaria, Denmark, Sweden, The Bahamas, Norway, Tajikistan, Austria, Greece, Eswatini, Rwanda, Cuba, Moldova, Angola, Cambodia, Ghana.
We have been delivering Keyence elements all around the United Kingdom and anywhere in the earth for over 11 years. All instruments and constituents are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the prompt supplies from key European manufacturers and a low trade margin, we give our customers the most acceptable prices for all products displayed in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the needs of the manufacturing process. More than 4,000 consumers have already valued the high quality of the items we deliver and the professionalism of the FAMAGA employees.
To clarify the expense of Keyence GP-M010 and shipment time, you can complete a special inquiry form on our website, dispatch a list of essential equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best trade offer for you and give short shipment times to any urban place in the United Kingdom and any country in the world.
Model | GP-M010 | |
Rated pressure | -0.1 to +1 MPa (-1 to +10 bar) | |
Possible display range | -0.210 to +1.110 MPa (-2.10 to +11.10 bar) | |
Zero-cut pressure value | ±0.5% of F.S. | |
Burst pressure | 15 MPa (150 bar) | |
Display resolution | 0.001 MPa (0.01 bar) | |
Fluid type | Gas or liquid that will not corrode the liquid contact part | |
Type of pressure | Gage pressure | |
Precision | ±1.0% of F.S. or less*1 | |
Repeatability | ±0.3% of F.S. or less*2 | |
Temperature characteristics | ±0.6% of F.S./10°C | |
Connection diameter | G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) | |
Box rotation angle | Maximum 330° | |
Medium temperature | -20 to +100°C (no freezing/condensation)*3 | |
Power supply voltage | 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS | |
Current consumption | 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 | |
Display method | 4 column, digital LED, red/Vertical inversion display possible | |
Operation display light | Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) | |
Hysteresis | During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) During window mode: fixed (0.5% of F.S.) | |
Response | Control output | Selectable from 3 to 5000 ms |
Analogue output | As above + 2 ms (90% response) | |
Output | Output 1 control output | NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable |
Output 2 replacement type | Control output | |
Analogue output | 4-20 mA, maximum load resistance 500 ? (When the electric voltage is more than 20 V)*5 | |
Environmental resistance | Enclosure rating | IP67 |
Pressure resistance | 4 MPa (40 bar) | |
Ambient temperature | -20 to +80 °C (No freezing and no condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes) | |
Shock resistance | IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) | |
Material properties | Port/diaphragm | Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
Other parts | Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass. | |
Applicable cable | M12 connector 4 pin | |
Weight | Approx. 150 g | |
*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C. *2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition. *3 When the temperature of the piping exceeds 80°C, do not connect the cable. *4 Consumption current including output is 0.6 A and under. *5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} ? When 23-30V: R = 622 ? |