Name
FD-XS8
Type
Process Sensor
Description
FD-XS8 Sensor head + FD-XA1 Controller + FD-XC8R1 Clamp set
Stock availability:
On request
If you want to buy Keyence FD-XS8 , additionally order other industrial equipment and constituent parts for its mend, please connect FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Botswana, Slovenia, Thailand, Senegal, Romania, Tunisia, Japan, Russia, Bolivia, Liberia, Israel, Kiribati, Malaysia, Cameroon, Jamaica, Kenya, Afghanistan, The Bahamas, Qatar, Turkmenistan, Comoros, Turkey, Estonia, Congo, Nigeria, Laos, Palestine, Guyana, The Gambia, Ghana, Kuwait, Austria, Serbia, Angola, Kazakhstan, United Arab Emirates, Ecuador, Belize.
We have been delivering Keyence items throughout the UK and anywhere in the earth for over 11 years. All apparatus and materials are provided with appropriate quality certificates, together with a guarantee from the official creator of products Keyence.
Thanks to the prompt supplies from leading European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products exposed in our catalogue. If necessary, our qualified specialists will help you elect industrial equipment that will fully meet the requirements of the production process. More than 4,000 consumers have already appreciated the high quality of the items we bring and the professionalism of the FAMAGA workers.
To clarify the charge of Keyence FD-XS8 and shipment time, you can complete a special inquiry form on our website, dispatch a list of necessary equipment by E-mail or call to the quoted phone numbers. We will be able to make the best financial offer for you and provide adequate delivery times to any urban place in the UK and any country in the globe.
Model | FD-XS8 | |||
Supported pipe materials | Metal pipes, Plastic pipes (soft/hard) *1 | |||
Supported fluids | Liquids (water, oil, adhesive, grease, chemical solution, etc.) *1 | |||
Supported fluid temperature | 0 °C (no freezing on the pipe surface) to 100 °C (Pipe surface temperature) | |||
Clamp set model | Plastic pipe/tube attachment | FD-XC8R1, FD-XC8R2, FD-XC8R3 | ||
Metal pipe attachment | FD-XC8M | |||
Maximum rated flow rate | Outer diameter of pipe o 6, 1/4 ' (6.35 mm) : 0 to 3000 mL/min Outer diameter of pipe o 8: 0 to 8000 mL/min | |||
Zero cut flow rate | 40 mL/min*2 (variable, default) | |||
Display resolution | Instantaneous flow rate | 0.1/1/10 mL/min (Displayed on controller) | ||
Shot amount | 0.001/0.01/0.1/1 mL (Displayed on controller) | |||
Repeatability | Plastic pipe /tube attachment | Response time: 50 ms | F.S. | ±0.1 %*3*4 |
Instantaneous flow rate | Outer diameter of pipe o 6, 1/4 ' (6.35 mm): ±3 mL/min Outer diameter of pipe o 8: ±8 mL/min*3*4 | |||
Response time: 500 ms | Outer diameter of pipe o 6, 1/4 ' (6.35 mm) : ±1.0 mL/min Outer diameter of pipe o 8: ±2.6 mL/min*3 | |||
Metal pipe attachment | Response time: 50 ms | F.S. | Outer diameter of pipe o 6, 1/4 ' (6.35 mm) : ±0.3 % Outer diameter of pipe o 8: ±0.15 %*3*4 | |
Instantaneous flow rate | Outer diameter of pipe o 6, 1/4 ' (6.35 mm) : ±9 mL/min Outer diameter of pipe o 8: ±12 mL/min*3*4 | |||
Response time: 500 ms | Outer diameter of pipe o 6, 1/4 ' (6.35 mm) : ±2.9 mL/min Outer diameter of pipe o 8: ±3.8 mL/min*3 | |||
Hysteresis | Variable | |||
Integrated unit display | 0.1/1/10/100/1000/10000 mL (displayed on controller) | |||
Display method | Status indicator | |||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) , IP68G (JIS C0920) *5 | ||
Operating ambient temperature | -10 to 60 °C (No freezing) | |||
Operating ambient humidity | 35 % to 85 %RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X,Y,Z direction | |||
Shock resistance | 50 G 11 ms, 3 times each for X,Y,Z direction | |||
Material | Sensor head | Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM | ||
Clamp set | For plastic pipe | Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7 | ||
For metal pipe | Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7 | |||
Weight | Approx. 250 g | |||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe. *2 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *3 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale value) listed in the table according to the rated flow range. *4 The longer the response time is set, the more repeatability is improved. As a guideline, use v (50 ms/response time) times. *5 The connector part of the sensor head cable is IP65/IP67. |