Process Sensor RD-50RK Keyence
Process Sensor RD-50RK Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence RD-50RK

Manufacturer

Keyence

Country

Japan

Name

RD-50RK

Type

Process Sensor

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications RD-50RK

If you want to buy Keyence RD-50RK , as well as order other industrial equipment and replacement parts for its adjust, please contact FAMAGA .

We have been delivering Keyence goods all over the UK and anywhere in the world for over 9 years. All equipment and constituents are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.

Thanks to the direct deliveries from global European manufacturers and a minimum trade margin, we suggest our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the goods we supply and the professionalism of the FAMAGA employees.

To clarify the price of Keyence RD-50RK and delivery terms, you can fill in a special filling form on our website, give a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any place in the UK and any country in the world.

Features RD-50RK

Main Unit, RS-232C Type
Model RD-50RK
Measurement function DC voltage measurement, DC current measurement
A/D converting system Successive comparison
Measurement range ±5 VDC, ±10 VDC, 4 to 20 mA DC (selectable)
Display range -19999 to +39999
Measurement accuracy ±0.03 % of F.S. (at ±5 VDC range), ±0.03 % of F.S. (at ±10 VDC range) ±0.05 % of F.S. (at 4 to 20 mA DC range)
Input Impedance 1 M? (for voltage input), 350 ? (for current input)
System Single-ended
Number of inputs 2
Sampling rate 2,000 times/second
Display speed 20 times/second
Display power 7-segment 3-colour LED (character height: 15.24 mm)
Over-range alarm FFFF is displayed
Control input NPN open-collector or non-voltage contact signal
Control input Timing input
Hold reset input
Auto-zero input
External setting input
Controloutput Setting method 4 steps x 8 programmable setups (selectable)
Signal 5 x NPN (HH, HI, GO, LO, LL): 100 mA max. (40 V max.)
Response time 1 ms (when average number 1)*1
OFF-delay time 60 ms (ON/OFF selectable)
Analogue output voltage Output voltage ±10 VDC
Impedance 100 ?
Response time 1 ms (when average number 1)*2
Interface Data output and control input through RS-232C
Major functions MDL, digital fi lter, auto-zero, offset, input, data processing (10 modes), tolerance limit storage (up to 8 sets), decimal point shift, error message display, etc.
Rating Power voltage 24 VDC ±10 %, Ripple (P-P) 10 % or less
Current consumption 270 mA or less
Environmental resistance Ambient temperature 0 to +50 °C
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Weight Approx. 700 g (excluding fi ttings)
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP output converter. *2 Requires 1.5 ms every second during self-compensation sequence to prevent temperature fl uctuations.