We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence RD-50RK , as well as order other industrial equipment and replacement parts for its adjust, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Kuwait, Grenada, Guatemala, Philippines, Senegal, Monaco, Australia, Malawi, Luxembourg, Italy, Austria, Albania, Gambia, Suriname, Sudan, India, South Korea, Mali, Oman, Liechtenstein, Madagascar, Vietnam, Central African Republic, Mauritania, Angola, Estonia, Iran, Niger, Costa Rica, Guinea, Egypt, Burkina Faso, Palestine, Azerbaijan, Honduras, Indonesia, Bahrain, Zambia, Yemen.
We have been delivering Keyence goods all over the UK and anywhere in the world for over 9 years. All equipment and constituents are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.
Thanks to the direct deliveries from global European manufacturers and a minimum trade margin, we suggest our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the goods we supply and the professionalism of the FAMAGA employees.
To clarify the price of Keyence RD-50RK and delivery terms, you can fill in a special filling form on our website, give a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any place in the UK and any country in the world.
Model | RD-50RK | |
Measurement function | DC voltage measurement, DC current measurement | |
A/D converting system | Successive comparison | |
Measurement range | ±5 VDC, ±10 VDC, 4 to 20 mA DC (selectable) | |
Display range | -19999 to +39999 | |
Measurement accuracy | ±0.03 % of F.S. (at ±5 VDC range), ±0.03 % of F.S. (at ±10 VDC range) ±0.05 % of F.S. (at 4 to 20 mA DC range) | |
Input | Impedance | 1 M? (for voltage input), 350 ? (for current input) |
System | Single-ended | |
Number of inputs | 2 | |
Sampling rate | 2,000 times/second | |
Display speed | 20 times/second | |
Display power | 7-segment 3-colour LED (character height: 15.24 mm) | |
Over-range alarm | FFFF is displayed | |
Control input | NPN open-collector or non-voltage contact signal | |
Control input | Timing input | |
Hold reset input | ||
Auto-zero input | ||
External setting input | ||
Controloutput | Setting method | 4 steps x 8 programmable setups (selectable) |
Signal | 5 x NPN (HH, HI, GO, LO, LL): 100 mA max. (40 V max.) | |
Response time | 1 ms (when average number 1)*1 | |
OFF-delay time | 60 ms (ON/OFF selectable) | |
Analogue output voltage | Output voltage | ±10 VDC |
Impedance | 100 ? | |
Response time | 1 ms (when average number 1)*2 | |
Interface | Data output and control input through RS-232C | |
Major functions | MDL, digital fi lter, auto-zero, offset, input, data processing (10 modes), tolerance limit storage (up to 8 sets), decimal point shift, error message display, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 270 mA or less | |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Weight | Approx. 700 g (excluding fi ttings) | |
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP output converter. *2 Requires 1.5 ms every second during self-compensation sequence to prevent temperature fl uctuations. |