We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to gain Keyence LS-9030M , additionally demand other industrial equipment and constituent parts for its fix, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Zimbabwe, Myanmar, The Bahamas, Cape Verde, Senegal, Comoros, Papua New Guinea, Burkina Faso, Namibia, Italy, Djibouti, Lesotho, Liberia, Thailand, Mozambique, Tanzania, Guatemala, Qatar, Colombia, Paraguay, Vietnam, Saudi Arabia, Guyana, El Salvador, Switzerland, Turkmenistan, Suriname, Norway, Yemen, Rwanda, Bhutan, Bahrain, Tonga, Nigeria, Argentina, Macedonia, Dominica, Sri Lanka, Indonesia, The Gambia, Estonia, Sierra Leone, Slovenia, South Korea, Belarus.
We have been shipping,conveying Keyence units all around Britain and anywhere in the earth for over 10 years. All apparatus and replacements are provided with appropriate quality certificates, along with a guarantee from the official manufacturer of products Keyence.
Thanks to the shortest shipment from prominent European manufacturers and a minimal trade margin, we suggest our customers the most acceptable prices for all products exposed in our catalogue. If necessary, our certified experts will help you choose industrial instruments that will fully meet the requirements of the manufacturing process. More than 4,000 customers have already comprehended the high quality of the goods we transport and the dedication of the FAMAGA workers.
To define the charge of Keyence LS-9030M and delivery times, you can complete a special filling form on our website, dispatch a list of desirable apparatus by E-mail or call to the specified phone numbers. We will be able to devise the best trade offer for you and prepare optimal shipment times to any place in Great Britain and any country in the planet.
Model | LS-9030M*1 | |
Type | Head: Standard model | |
Measurement range | 0.3 mm (0.08 mm) to 30 mm | |
Smallest detectable object | 0.3 mm (0.08 mm) | |
Transmitter/receiver distance | 160 ±40 mm | |
Repeatability | ±0.1 µm*2 | |
Measurement accuracy | ±2 µm*3 | |
Sampling cycle | 16,000 samples/sec.*4 | |
Transmitter/receiver direction and position detection | Detection area | 20 x 24 mm |
Smallest detectable object | 0.3 mm | |
Repeatability | ±0.2 mm*5 | |
Sampling cycle | 4,000 samples/sec. | |
Light source | InGaN green LED | |
Monitor camera | Provided | |
Environmental resistance | Enclosure rating | IP67 (including connector) |
Ambient light | Incandescent lamp/Fluorescent lamp: 3,000 lux or lower | |
Ambient temperature | 0 to +50 °C | |
Relative humidity | 20 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 15 G/6 ms | |
Material | Aluminum | |
Weight | Transmitter: Approx. 440 g Receiver: Approx. 500 g Base: Approx. 430 g | |
*1 The values in brackets are measured in ultra-thin mode. For details on the accuracy of ultra-thin mode, contact the nearest KEYENCE office. *2 A ±2? margin of error when measuring a o10 mm rod in the centre of the measurement area using outer diameter mode with the average measurement number set as 2,048 times. *3 Margin of error when a moving o10 mm rod is measured in the 10 mm x 20 mm measurement area using outer diameter mode. *4 The sampling cycle is changed by the number of OUT set, and by the use of the mutual interference prevention function. *5 A ±2? margin of error when measuring the position of a o10 mm rod in the centre of the measurement area with the average measurement number set as 512 times. |