We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence LS-3033 , as well as order other industrial equipment and constituent parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Guatemala, Denmark, Saudi Arabia, Latvia, Austria, Panama, Haiti, Zambia, Brunei, Swaziland, Grenada, Ethiopia, Azerbaijan, Armenia, Japan, Afghanistan, Iraq, Sweden, Norway, Nigeria, Serbia, Lebanon, Dominica, The Bahamas, Togo, The Gambia, Rwanda, Switzerland, Indonesia, New Zealand, Bahrain, Belarus, Madagascar, Bhutan, Yemen, Mauritius, Peru, Tonga, Senegal, South Korea, Kenya, Uzbekistan, Suriname.
We have been delivering Keyence elements all around the UK and anywhere in the world for over 11 years. All equipment and replacements are provided with appropriate quality certificates, together with a guarantee from the official creator of products Keyence.
Thanks to the direct deliveries from major European manufacturers and a minimum trade margin, we propose our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the elements we supply and the professionalism of the FAMAGA employees.
To clarify the expense of Keyence LS-3033 and shipment time, you can complete a special inquiry form on our website, dispatch a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any urban place in the UK and any country in the world.
Model | LS-3033 | |
Type | Standard | |
Applicable controller | LS-3100/LS-3100D | |
Scanning head type | Separate | |
Measurement range | 0.5 to 30 mm | |
Smallest detectable object | 0.5 mm | |
Transmitter/receiver distance | 120 ±40 mm*1 | |
Repeatability | ±0.3 µm (number of averaging measurements: 512) | |
Measurement accuracy | ±2 µm max.*2 | |
Laser scan rate | 400 scans/s | |
Laser scan velocity | 63 m/s | |
Laser scan range | Approx. 33 mm | |
Display | Minimum display unit | 0.1 µm |
Terminal block I/O | Analogue voltage | ±6 V, Output impedance: 0 ? |
Control output | Relay output: 3PST-NO contact, 250 VAC, 2 A (resistive load) | |
Control input | Hold synchronous, LASER REMOTE, PROGRAM SELECT (Program Nos. 1 to 5) Non-voltage input (contact/solid state) | |
Light source | Invisible infrared semiconductor laser Output: 3.0 mW (FDA) /55 µW (IEC), Wavelength: 780 nm, Pulse duration: 111 µs Laser Class: Class I Laser Product (FDA (CDRH) Part 1040.10), Class 1 Laser Product (IEC 60825-1) | |
Interface | RS-232C | Optional |
GP-IB | ||
BCD | ||
Rating | Power voltage | 85 to 264 VAC, 50/60 Hz |
Power consumption | 40 VA max. | |
Environmental resistance | Ambient temperature | 0 to +45 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Weight | T: 0.5 kg, R: 0.4 kg | |
*1 'T' indicates a transmitter, 'R' indicates a receiver. *2 When a rod 10 mm in diameter is measured in a 2 x 20 mm, 4 x 20 mm, or 10 x 20 mm measuring area. |