We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence LJ-V7080 , as well as order other industrial equipment and constituent parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Mauritania, Swaziland, Nicaragua, San Marino, Brazil, Rwanda, Kuwait, Thailand, India, El Salvador, Brunei, Saudi Arabia, Macedonia, Tonga, Benin, The Bahamas, South Africa, Bulgaria, Bosnia and Herzegovina, Burkina Faso, Hungary, Kenya, Niger, Haiti, Lesotho, Switzerland, Honduras, United Arab Emirates, Sudan, Suriname, Iraq, Paraguay, Dominica, Vietnam, Peru, Belarus, Cyprus, Argentina, Bhutan, Monaco, Barbados, Dominican Republic, Cambodia, Denmark, Yemen.
We have been delivering Keyence products all around the UK and anywhere in the world for over 11 years. All equipment and components are provided with appropriate quality certificates, together with a guarantee from the official creator of products Keyence.
Thanks to the direct deliveries from leading European manufacturers and a minimum trade margin, we offer our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the products we supply and the professionalism of the FAMAGA employees.
To clarify the cost of Keyence LJ-V7080 and shipment time, you can complete a special inquiry form on our website, dispatch a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any urban place in the UK and any country in the world.
Model | LJ-V7080 | |
Mounting conditions | Diffuse reflection | |
Reference distance | 80 mm | |
Measurement range | Z-axis (height) | ±23 mm (F.S.=46 mm) |
X-axis (width) | NEAR side | 25 mm |
Reference distance | 32 mm | |
Far side | 39 mm | |
Light source | Type | Blue semiconductor laser |
Wavelength | 405 nm (visible beam) | |
Laser class | Class 2 Laser Product (IEC60825-1, FDA(CDRH) Part 1040.10*1) | |
Output | 4.8 mW | |
Spot size (reference distance) | Approx. 48 mm ? 48 µm | |
Repeatability | Z-axis (height) | 0.5 µm*2*3 |
X-axis (width) | 10 µm*2*4 | |
Linearity | Z-axis (height) | ±0.1% of F.S.*5 |
Profile data interval | X-axis (width) | 50 µm |
Sampling cycle (trigger interval) | Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*6 | |
Temperature characteristics | 0.01% of F.S./°C | |
Environmental resistance | Enclosure rating | IP67 (IEC60529)*7 |
Ambient light | Incandescent lamp: 10,000 lux max.*8 | |
Ambient temperature | 0 to +45 °C*9 | |
Relative humidity | 20 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 57 Hz, Double amplitude 1.5 mm, 3 hours in each of the X, Y, and Z directions | |
Shock resistance | 15 G/6 ms | |
Material | Aluminium | |
Weight | Approx. 400 g | |
*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No. 50. *2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging. *3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default. *4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default. *5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default. *6 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON. All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default. *7 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected. *8 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper. *9 The sensor head must be mounted on a metal plate for use. |