We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence LT-9011M , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Eritrea, Haiti, Cameroon, Romania, Eswatini, Cape Verde, Bahrain, Malawi, Brunei, Bahamas, Kuwait, China, Tanzania, Guyana, Gabon, Nigeria, Austria, Cambodia, Monaco, Central African Republic, Angola, Cuba, Honduras, Antigua and Barbuda, Burkina Faso, Malaysia, Japan, Bulgaria, Israel, Benin, Burundi, Lesotho, Algeria, Slovenia, Ecuador, Mauritius, Panama, United Arab Emirates, Tajikistan, Rwanda, Venezuela, Costa Rica, Egypt, Sri Lanka, The Bahamas, Congo.
We have been delivering Keyence units throughout the UK and anywhere in the world for over 10 years. All equipment and parts are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from prominent European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we supply and the professionalism of the FAMAGA employees.
To clarify the value of Keyence LT-9011M and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.
Model | LT-9011M | ||
Type | High-accuracy | ||
Measurement range | ±0.3 mm | ||
Reference distance | 6 mm | ||
Light source | Type | Red semiconductor laser | |
Wavelength | 655 nm | ||
Output | 170 µW (IEC 60825-1) /3.0 µW (FDA (CDRH) Part 1040.10) | ||
Laser Class | Class IIa Laser Product (FDA (CDRH) Part 1040.10) Class 1 Laser Product (IEC 60825-1) | ||
Spot diameter | Approx. o2 µm | ||
Scan width/interval | 0 to 1,100 µm (6 steps) /1 to 10 µm (4 steps) | ||
Resolution | 0.3 µm*1 | ||
Linearity | ±0.5 % of F.S.*1 | ||
Sampling cycle | 640 µs to 356 ms (14 steps)*2 | ||
Display | Minimumdisplayable unit | 0.1 µm*3, 1 µm2, 0.01 ° | |
Display range | ±9,999.99 µm, ±999,999 µm2, 9,999.99 ° | ||
Microscope function | Available | ||
Display cycle | 10 times/sec.*4 | ||
Terminal block | Analogue output | ±10 V x 2 outputs, output impedance: 100 ? | |
Timing input | Non-voltage input | ||
Reset input | |||
Auto-zero input | |||
Monitor dedicated power supply | 24 VDC*5 | ||
Control I/O | Judgment mode | 3-step limits output | For OUT1 and OUT2, and NPN open collector output*6 |
Binary mode | Binary output | Measured data output (21 bits), OUT1/OUT2/PROFILE selectable NPN open collector output*6 | |
Strobe output | NPN open collector output*6 | ||
Binary selector output | |||
Binary selection input | Non-voltage input*6 | ||
Stability output | NPN open collector output | ||
Laser remote input | Non-voltage input | ||
Program switching input | Non-voltage input x 3 inputs | ||
RS-232C interface | Measured data output and control I/O (Selectable up to baud rate 115200 bps.) | ||
Video output | NTSC compliant (PIN connector) | ||
Microscope function | Function presence/absence | Compatible | |
Field of view | 1.3 mm x 1.05 mm | ||
Type | Available | ||
Illumination light source | Infrared LED (wavelength: 870 nm) | ||
Main functions | Displacement mode | Distance measurement, Transparent objectthickness measurement, Angle measurement,Relative angle measurement, Surface selection,Dark-out, Mask, Trend graph display, and Scanwidth/interval change*7 | |
Profile mode | Area selection (Average, Maximum, Minimum, Maximum-to-minimum, Area) Area calculation, Scan width/interval change, Dark-out, Smoothing, Averaging, and Profile data output*8 | ||
Common | Light intensity accumulation, Microscope (LT-9501H, LT-9501HSO (5654) only), Tolerance judgement, 8-program registration, Calibration, Averaging, Hold modes, Auto-zero, and interface language selection | ||
Temperature characteristics (20 to 30°C) | ±0.5% of F.S. | ||
Rating | Power voltage | 100 to 240 VAC ±10 %, 50/60 Hz | |
Power consumption | 110VA or less | ||
Environmental resistance | Pollution degree | 2 | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp/fluorescent lamp: 10,000 lux max. | ||
Ambient temperature | 0 to +35 °C | ||
Relative humidity | 35 to 85 % RH (No condensation) | ||
Weight | Approx. 400 g | ||
*1 The value when the measurement target is a mirrored surface object measured in displacement mode, scan width/interval 120 µm/2 µm, and 8-times average *2 Sampling cycle differs according to the manufacturing variation of individual measuring units. The value when the FINE mode is set to OFF. *3 Display changes every ±0.3 µm. *4 Varies depending on the setting *5 Dedicated power supply for the monitor specified by KEYENCE. *6 Select either the Limits mode or the Binary mode. *7 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).)The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V.The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower. *8 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).) The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V. The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower. |