We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence LK-G5001P , as well as order other industrial equipment and replacement parts for its adjust, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Nigeria, India, Philippines, Iraq, Latvia, Chad, Finland, Burkina Faso, Guinea-Bissau, Honduras, Morocco, Andorra, Colombia, Switzerland, Guyana, Hungary, Mozambique, Serbia, Sweden, Barbados, Suriname, Monaco, Kenya, Albania, South Sudan, Moldova, Kazakhstan, The Gambia, Kuwait, Nicaragua, Cuba, Côte d\'Ivoire, Bahrain, Brunei, Czech Republic, Tajikistan, Gabon, Lithuania, Libya, Liechtenstein, Estonia.
We have been delivering Keyence units all over the UK and anywhere in the world for over 9 years. All equipment and parts are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.
Thanks to the direct deliveries from prominent European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we supply and the professionalism of the FAMAGA employees.
To clarify the value of Keyence LK-G5001P and delivery terms, you can fill in a special filling form on our website, give a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any place in the UK and any country in the world.
Model | LK-G5001P | |
Type | Separate type Main controller | |
Sensor head compatibility | Compatible | |
No. of connectable sensor heads | 2 | |
Display | Minimum display unit | 0.001 µm |
Display range | ±999.999 µm to ±9999.99 mm (7 settings selectable) | |
Display cycle | Approx 10 times/sec. | |
Display interface | Display port | Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected |
LED indicator | LASER ON | |
Terminal block | Analogue output voltage | ±10 V output, Output impedance: 100 ?*1 |
Analogue current output | 4 to 20 mA, Maximum load resistance: 350 ?*1 | |
No. of analogue outputs | 2*1 | |
TIMING 1 input | Voltage input*2 | |
RESET 1 input | ||
Auto-zero 1 input | ||
Laser remote input | Non-voltage input*1 | |
Alarm output | PNP open-collector output*1 | |
General comparator output | ||
Expansion connector | TIMING input | Voltage input*1 |
RESET input | ||
Auto-zero input | ||
Program switching input | ||
Binary selection input | ||
Alarm output | PNP open-collector output*1 | |
Comparator output | ||
Binary output | ||
RS-232C interface | Baud rate: 9600 to 115200 bps Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd | |
USB interface | USB 2.0 Hi-Speed compliant*3 | |
Ethernet interface | 100Base-TX/10Base-T*4 | |
EtherNet/IPTMinterface | Cyclic communication (implicit messaging) Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*5 | |
PLC-Link | The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series EtherNet/IPTM, CC-Link, and DeviceNetTM cannot be used in conjunction with PLC-Link | |
Head expansion unit connector | Up to 10 head expansion units can be connected to one main controller | |
Expansion unit connector | Either of the CC-Link unit (LK-CC100) or DeviceNetTM unit (LK-DN100) can be connected | |
Power supply | Power supply voltage | 24 VDC ±10% |
Maximum current consumption | 0.6 A or less with 1 head/3.5 A or less with 12 heads | |
Environmental resistance | Ambient temperature | When one or less head expansion unit is connected: 0 to +50 °C. When two or more head expansion units are connected: 0 to +40 °C. |
Relative humidity | 35 to 85 % RH (No condensation) | |
Weight | Approx. 600 g | |
*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max. PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max. Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max. Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to 'Precautions on wiring' in the User's Manual. *2 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max. PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max. Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max. Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to 'Precautions on wiring' in the User's Manual. This input is applied to all of the synchronised OUT. *3 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down. *4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units. *5 The EtherNet/IPTM interface cannot be used when a CC-Link unit or a DeviceNetTM unit is installed. EtherNet/IPTM is supported by the latest controllers. For details on which controllers support EtherNet/IPTM , contact your nearest KEYENCE office. |