We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence LK-G3000V , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Singapore, Georgia, Zimbabwe, Panama, Yemen, Andorra, Denmark, Saudi Arabia, Togo, Sierra Leone, Lesotho, Sri Lanka, South Africa, Palestine, Dominica, Lithuania, Kenya, Eswatini, New Zealand, Central African Republic, Lebanon, Algeria, Tonga, Mauritania, Egypt, Indonesia, Paraguay, Greece, Tunisia, Iraq, Nicaragua, Slovenia, Sweden, Iran, Japan, Burkina Faso, Albania, Kuwait, Jamaica, India, Peru, Thailand, Cambodia.
We have been delivering Keyence elements throughout the UK and anywhere in the world for over 10 years. All equipment and replacements are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from major European manufacturers and a minimum trade margin, we propose our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the elements we supply and the professionalism of the FAMAGA employees.
To clarify the expense of Keyence LK-G3000V and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.
Model | LK-G3000V*1 | |
Separate type | LK-G3000/LK-GD500*2 | |
Type | All-in-one model | |
Head compatibility | All LK-G sensor heads are compatible | |
Connectable number of heads | Maximum of 2 units | |
Display | Minimum display unit | 0.01 µm |
Display range | ±9,999.99 mm to ±9,999.99 µm (Selectable from six levels) | |
Display cycle | 10 times/sec | |
Terminal block | Analogue voltage output | ±10 V x 2 outputs, output impedance: 100 ? |
Analogue current output | 4 to 20 mA x 2 outputs, maximum load resistance: 350 ? | |
Timing input | For OUT1, non-voltage input | |
Reset input | ||
Auto-zero input | ||
Laser remote interlock input | Non-voltage input | |
Comparator output | For OUT1, NPN open-collector output | |
Alarm output | For OUT1, NPN open-collector output (N.C.) | |
Expansion connector | Timing input | For OUT2, non-voltage input |
Reset input | ||
Auto-zero input | ||
Program switching input | Non-voltage input x 3 inputs | |
Laser-Off input | For Head A/Head B, non-voltage input | |
Comparator output | For OUT2, NPN open-collector output | |
Alarm output | For OUT2, NPN open-collector output (N.C.) | |
Binary | Binary output | Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output |
Strobe output | NPN open-collector output | |
Binary selector output | ||
Binary selector input | Non-voltage input | |
RS-232C interface | Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable) | |
USB interface | In conformity with USB Revision 2.0 Full speed (USB1.1 compatible) | |
Major functions | 2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO, Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode, ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target, Statistics processing, Connection of setting support software, Selectable head-mounting, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 500 mA or less with 1 head/600 mA or less with 2 heads | |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Weight | Approx. 480 g (including the cable) | |
*1 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 1 V max. The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current. *2 LK-G3000 can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W). |