Mounting bracket FS-V11P Keyence
Mounting bracket FS-V11P Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence FS-V11P

Manufacturer

Keyence

Country

Japan

Name

FS-V11P

Type

Mounting bracket

Description

VERSTÄRKER

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications FS-V11P

Keyence Fibreoptic Amplifier

Features FS-V11P

Fibre Amplifier, Cable Type, Main Unit, PNP
Model FS-V11P
Type Main unit
Output PNP
Light source Red LED
Response time 250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO)
Operation mode LIGHT-ON/DARK-ON (switch-selectable)
Indicator lamp Display indicator: Red LED Digital LED monitor: Seven segments, four digits, red LED Bar LED monitor: One orange LED and six green LEDs
Timer function ON-delay: 40 ms /OFF-delay: 10 ms /Timer OFF (switch-selectable)
Control output PNP open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.
Protection circuit Reversed polarity protection, over-current protection, surge absorber
Unit expansion Up to 16 expansion units can be connected (a total of 17 units).*1
Mutual interference suppression FINE : 4, TURBO/SUPER: 8
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*2
Current consumption 50 mA or less
Environmental resistance Ambient light Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.
Ambient temperature -10 to +55 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Case material Polycarbonate
Weight Approx. 80 g
*1 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 3 to 10 Units: -10 to 50°C, 11 to 16 Units: -10 to 45°C *2 Neither the FS-V12 nor the FS-V10 can be used as a standalone unit.