Mounting bracket FS-N41C Keyence
Mounting bracket FS-N41C Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence FS-N41C

Manufacturer

Keyence

Country

Japan

Name

FS-N41C

Type

Mounting bracket

Description

KEYENCE Faseroptischer Sensorverstärker FS-N41C

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications FS-N41C

If you want to gain Keyence FS-N41C , along with request other industrial equipment and constituent parts for its repair, please call FAMAGA .

We have been distributing Keyence goods all over the UK and anywhere in the world for over 11 years. All apparatus and replacements are provided with appropriate quality certificates, along with a guarantee from the official creator of products Keyence.

Thanks to the direct deliveries from key European manufacturers and a low trade margin, we suggest our customers the most acceptable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you elect industrial apparatus that will fully meet the necessities of the operation procedure. More than 4,000 customers have already appreciated the high quality of the items we deliver and the professionalism of the FAMAGA workers.

To clarify the value of Keyence FS-N41C and shipment time, you can complete a special filling form on our website, dispatch a list of necessary equipment by E-mail or call to the specified phone numbers. We will be able to create the best commercial offer for you and give optimal delivery times to any urban place in Britain and any country in the earth.

Features FS-N41C

Fibre Amplifier, M8 Connector Type, Main Unit
Model FS-N41C*1
Type M8 Connector*2
Main unit/expansion unit Main unit
Number of control outputs 2*3
Number of external inputs 1*3
Light source LED Transmitter side: Red, four-element LED (wavelength 660 nm)
Response time 23 µs (S-HSPD*4)/50 µs (HSPD*5) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)
Control output Open-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit) Residual voltage NPN 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA) PNP 1.6 V or less (output current 10 mA or less) / 2.2 V or less (output current 10 to 100 mA)
External input Input time 2 ms (ON) / 20 ms (OFF) or longer*6
Protection circuit Protection against reverse power connection, output overcurrent, output surge, and reverse output connection
Mutual interference prevention S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units (The mutual interference prevention values are twice those shown here when Double is set.)
Power supply Power voltage 10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*7
Current consumption During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V) ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8
Environmental resistance Ambient light Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less
Operating ambient temperature -20 °C to +55 °C (no freezing)*9
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X, Y, and Z axes
Shock resistance 500 m/s2 , 3 times each for X, Y, and Z axes
Case material Main unit and cover: polycarbonate
Weight Approx. 25 g
*1 IO-Link Specification V.1.1/COM2 (38.4 kbps) is supported. *2 Ensure the cable length is 30 m or less for the M8 connector type. Ensure the cable length is 20 meters or less when connecting by way of IO-Link. *3 Output 2 and the external input are selectable. *4 Restrictions when S-HSPD is selected Output 2 of dual output types is fixed to OFF. IO-Link communication cannot be used. Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *5 Restrictions when HSPD is selected Display Gain cannot be used. *6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *9 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C. When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.