Manufacturer
Keyence
Country
Japan
Name
FS-N41C
Type
Mounting bracket
Description
KEYENCE Faseroptischer Sensorverstärker FS-N41C
Stock availability:
On request
If you want to gain Keyence FS-N41C , along with request other industrial equipment and constituent parts for its repair, please call FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Burundi, Syria, Senegal, Czech Republic, Bhutan, Vietnam, Denmark, Lithuania, San Marino, Ukraine, Andorra, Israel, Sudan, Belarus, Guinea, Madagascar, Eswatini, Burkina Faso, New Zealand, Brunei, Niger, Togo, Zambia, Saudi Arabia, Luxembourg, Yemen, Mauritania, Myanmar, Iraq, Peru, Moldova, Dominica, Azerbaijan, Serbia, Malaysia, Liechtenstein, El Salvador, Sweden, Nigeria, Iran, Cyprus.
We have been distributing Keyence goods all over the UK and anywhere in the world for over 11 years. All apparatus and replacements are provided with appropriate quality certificates, along with a guarantee from the official creator of products Keyence.
Thanks to the direct deliveries from key European manufacturers and a low trade margin, we suggest our customers the most acceptable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you elect industrial apparatus that will fully meet the necessities of the operation procedure. More than 4,000 customers have already appreciated the high quality of the items we deliver and the professionalism of the FAMAGA workers.
To clarify the value of Keyence FS-N41C and shipment time, you can complete a special filling form on our website, dispatch a list of necessary equipment by E-mail or call to the specified phone numbers. We will be able to create the best commercial offer for you and give optimal delivery times to any urban place in Britain and any country in the earth.
Model | FS-N41C*1 | |
Type | M8 Connector*2 | |
Main unit/expansion unit | Main unit | |
Number of control outputs | 2*3 | |
Number of external inputs | 1*3 | |
Light source LED | Transmitter side: Red, four-element LED (wavelength 660 nm) | |
Response time | 23 µs (S-HSPD*4)/50 µs (HSPD*5) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA) | |
Control output | Open-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit) Residual voltage NPN 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA) PNP 1.6 V or less (output current 10 mA or less) / 2.2 V or less (output current 10 to 100 mA) | |
External input | Input time 2 ms (ON) / 20 ms (OFF) or longer*6 | |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, and reverse output connection | |
Mutual interference prevention | S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units (The mutual interference prevention values are twice those shown here when Double is set.) | |
Power supply | Power voltage | 10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*7 |
Current consumption | During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V) ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8 | |
Environmental resistance | Ambient light | Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less |
Operating ambient temperature | -20 °C to +55 °C (no freezing)*9 | |
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X, Y, and Z axes | |
Shock resistance | 500 m/s2 , 3 times each for X, Y, and Z axes | |
Case material | Main unit and cover: polycarbonate | |
Weight | Approx. 25 g | |
*1 IO-Link Specification V.1.1/COM2 (38.4 kbps) is supported. *2 Ensure the cable length is 30 m or less for the M8 connector type. Ensure the cable length is 20 meters or less when connecting by way of IO-Link. *3 Output 2 and the external input are selectable. *4 Restrictions when S-HSPD is selected Output 2 of dual output types is fixed to OFF. IO-Link communication cannot be used. Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *5 Restrictions when HSPD is selected Display Gain cannot be used. *6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *9 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C. When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space. |