We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence FS-N12CN , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, New Zealand, Ethiopia, Seychelles, Turkey, Bolivia, Belize, Thailand, Benin, Tanzania, Kenya, Uganda, The Gambia, Comoros, Afghanistan, Hungary, Malaysia, Slovakia, Kyrgyzstan, Sweden, Ghana, Haiti, Sierra Leone, Jamaica, Cape Verde, Kuwait, Austria, Venezuela, Bulgaria, Laos, Belgium, The Bahamas, Côte d\'Ivoire, Panama, South Africa, Finland, Cameroon, Estonia, China, Bosnia and Herzegovina, Philippines.
We have been delivering Keyence products throughout the UK and anywhere in the world for over 10 years. All equipment and components are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from leading European manufacturers and a minimum trade margin, we offer our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the products we supply and the professionalism of the FAMAGA employees.
To clarify the cost of Keyence FS-N12CN and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.
Model | FS-N12CN | |
Type | Standard 1 output M8 connector*1 | |
Output | NPN | |
Main unit/Expansion unit | Expansion unit | |
Control output | 1 NPN open collector 24 V, 1 output max: 100 mA or less, 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections), residual voltage 1 V or less | |
Monitor output (1-5 V) | - | |
External input | 1 Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.) | |
Response time | 50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) | |
Multiple connections to Expansion units | Up to 16 units can be connected total (two output type is treated as two units) | |
Light source | Red, 4-element LED | |
APC | ON/OFF switchable (Factory setting: OFF) | |
Number of interference prevention units | 0 for HIGH SPEED, 4 for FINE, 8 for TURBO/SUPER/ULTRA/MEGA (When set to double, the number of interference-prevention units will be doubled.) | |
Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current Consumption | Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2 Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*2 Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V) | |
Environmental resistance | Ambient light | Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less |
Ambient temperature | -20 to +55 °C (No freezing)*3 | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Case material | Both main unit and expansion unit housing material: Polycarbonate | |
Weight | Approx. 22 g | |
*1 Use a cable length of 30 m or less for M8 connector types. *2 Increases 100 mW (4.0 mA) for High Speed mode *3 One or two more units connected: -20 to +55 °C, 3 to 10 more units connected: -20 to +50 °C, 11 to 16 more units connected: -20 to +45 °C. When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting. |