We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence EX-V02P , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, China, Azerbaijan, Japan, Ghana, Hungary, Mauritius, The Bahamas, Djibouti, East Timor, Moldova, Mauritania, Madagascar, Armenia, Slovenia, Andorra, India, Senegal, Sierra Leone, Suriname, Kuwait, Egypt, Panama, Honduras, Colombia, Burkina Faso, Czech Republic, Libya, Tajikistan, Myanmar, Greece, Indonesia, South Sudan, The Gambia, Haiti, Swaziland, Côte d\'Ivoire, Palestine, Malaysia, Lithuania.
We have been delivering Keyence goods throughout the UK and anywhere in the world for over 10 years. All equipment and constituents are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from global European manufacturers and a minimum trade margin, we suggest our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the goods we supply and the professionalism of the FAMAGA employees.
To clarify the price of Keyence EX-V02P and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.
Model | EX-V02P*1 | |
Type | Amplifier Unit PNP | |
Shape | M10 x 18 mm Threaded | |
Measuring range | 0 to 2 mm | |
A/D converting system | ? | |
Display range | -19999 to +19999 | |
Linearity | ±0.3% of F.S. | |
Resolution (No. of averaging measurements: 64) | 0.4 µm | |
Sampling rate | 40000 samplings max./sec. *2 | |
Display speed | 20 times/sec. | |
Display power | 7-segment 2-colour LED | |
Over-range alarm | ±FFFF is displayed. | |
Control input | Timing input | 10 to 30 V is applied. |
Reset input | ||
Auto-zero input | ||
Judgment output: Inhibit input | ||
Synchronization/external settings input | ||
Control output | PNP: Applied voltage, 10 to 30 V | |
Controloutput | Setting method | Upper/lower 2-level setting x 4 patterns (selectable) |
Control output | Signal | PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
Controloutput | Response time | 0.075 ms (at maximum speed) |
OFF-delay time | 60 ms (ON/OFF selectable) | |
Strobe output | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) | |
Control output | Alarm output | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
Analogue output voltage | Output voltage | ±5V |
Impedance | 100 ? | |
Response time | 0.075 ms (at maximum speed) | |
Temperature characteristics | 0.07% of F.S./°C *3 | |
Major functions | FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 240 mA or less | |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Weight | Approx. 235 g | |
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm). When measuring aluminium, copper, or stainless steel targets, refer to the linear characteristics for these materials. *2 When the digital filter function is used, the sampling rate is 20000 sampling/sec. *3 When the distance between the sensor head and the target is within 50% of the measuring range. |