We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence IG-1550 , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Guinea-Bissau, Cyprus, Gabon, India, Lithuania, Colombia, Suriname, Grenada, South Africa, Romania, Kiribati, Kenya, Togo, Congo, Iran, Zambia, Kazakhstan, Niger, Rwanda, Estonia, Cameroon, Myanmar, Spain, Belarus, Sweden, El Salvador, Cambodia, Namibia, Bolivia, Denmark, Indonesia, Lesotho, Albania, Egypt, Peru, Iraq, Burkina Faso, Brunei, Swaziland, Liberia, Czech Republic, Lebanon.
We have been delivering Keyence units throughout the UK and anywhere in the world for over 10 years. All equipment and parts are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from prominent European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we supply and the professionalism of the FAMAGA employees.
To clarify the value of Keyence IG-1550 and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.
Model | IG-1550 | ||
Type | Panel mount | ||
Main unit/Expansion unit | Expansion unit | ||
Analogue output | No | ||
Power consumption (including Analogue current output) | Normal | 2880 mW or less (at 30 V: 96 mA or less)*1 | |
Power saving function (HALF) | 2300 mW (at 30 V: 77 mA or less)*1 | ||
Power saving function (ALL) | 2200 mW (at 30 V: 74 mA or less)*1 | ||
Digital display method | Dual 7-seg display Upper level: Red/Green, 2 colours, 5 digits Lower level: Green, 5 digits | ||
Display range | -99.999 to +99.999, -99.99 to +99.99, -99.9 to +99.9, -99 to +99 (selectable) | ||
Display resolution | 1 µm, 10 µm, 100 µm, 1,000 µm (selectable) | ||
Output | Judgment output (selectable between NPN and PNP) | NPN (PNP) open collector x3ch, 30 VDC (Power supply voltage) or less, residual voltage 1 V (2 V) or less, N.O./N.C. selectable Max. 50 mA/ch *2 | |
Response time (judgment output) | 1.96 to 4031.72 ms *3 | ||
Edge check output (selectable between NPN and PNP) | NPN (PNP) open collector x1ch, 30 VDC (Power supply voltage) or less, residual voltage 1 V (2 V) or less, N.O./N.C. selectable Max. 50 mA, *2 response time 20 ms | ||
Analogue output (selectable among ±5V, 1-5 V, 0-5 V, 4-20 mA) | Voltage output | Output range | ±5 V (full scale 10 V) |
Output resistance | 100 ? | ||
Maximum load resistance | ? | ||
Repetition accuracy | ±1 mV | ||
Display accuracy | ±0.05 % of F.S. | ||
Temperature characteristics | ±0.005 % of F.S./°C | ||
Update cycle | Same as sensor head sampling cycle | ||
Response time | Same as Response time (judgment output) | ||
Time constant | 10 µs (90 % response)*4 | ||
Current output | Output range | 4-20 mA (full scale 16 mA) | |
Output resistance | ? | ||
Maximum load resistance | 350 ? | ||
Repetition accuracy | ±1.5 µA | ||
Display accuracy | ±0.25 % of F.S. | ||
Temperature characteristics | ±0.01% of F.S./°C | ||
Update cycle | Same as sensor head sampling cycle | ||
Response time | Same as Response time (judgment output) | ||
Time constant | 30 µs (90 % response)*4 | ||
Input | Gain input | Input time: 20 ms or more, Response delay time: 120 ms or less (Nonvolatile memory (EEPROM) 1.5 s or less) | |
Reset input | Input time: 20 ms or more, Response delay time: 20 ms or less | ||
Timing input | Input time: 2 ms or more, Response delay time: 2 ms or less | ||
Zero shift input | Input time: 20 ms or more, Response delay time: 20 ms or less | ||
Bank A input/Bank B input | Input time: 20 ms or more, Response delay time: 20 ms or less *3 | ||
Laser emission stop input | Input time: 2 ms or more, Response delay time: 2 ms or less | ||
Rating | Power voltage | 10 to 30 VDC, including Ripple (P-P) 10 %, Class 2 or LPS | |
Environmental resistance | Pollution degree | 2 | |
Ambient temperature | -10 to +50 °C (No freezing) | ||
Relative humidity | 35 to 85 % RH (No condensation) | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | ||
Material | Main unit case/Front sheet: Polycarbonate, Key top: Polyacetal, Cable: PVC | ||
Accessories | Main body ? 1, Panel mounting bracket ? 1, Front protection cover ? 1, Power supply and input/output cable (2 m) ? 1, Expansion cable (50 mm) ? 1 | ||
Weight | Approx. 165 g (including supplied items) | ||
*1 The power consumption with slave units installed is the total of each amplifier unit's power consumption. *2 When expansion units are added: Max. 20 mA/ch *3 For more details, refer to the User's Manual. *4 Delay time that occurs from the analogue output circuit after the judgment is output. |