We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
IB-1500
Type
Mounting bracket
Description
LASER THRUBEAM SENSOR (AMPLIFIER UNIT)
Stock availability:
On request
If you want to purchase Keyence IB-1500 , in addition request other industrial equipment and constituent parts for its adjust, please approach FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Chile, Burkina Faso, Czech Republic, Niger, Honduras, Myanmar, Libya, Seychelles, South Sudan, Mozambique, Uzbekistan, Senegal, Malaysia, Belarus, Congo, South Korea, Liberia, Ukraine, Suriname, Rwanda, Guatemala, Bahrain, Iraq, Bangladesh, Hungary, Nicaragua, Guinea-Bissau, Lithuania, Sweden, Slovakia, Peru, Spain, Jamaica, Iran, Armenia, Namibia, Albania, Monaco, Eswatini, Côte d\'Ivoire, Serbia, Gabon, Cuba, Greece.
We have been shipping,conveying Keyence items throughout the United Kingdom and anywhere in the planet for over 11 years. All machinery and replacements are provided with appropriate quality certificates, with a guarantee from the official creator of products Keyence.
Thanks to the prompt supplies from major European manufacturers and a low trade margin, we suggest our customers the most fair costs for all products exhibited in our catalogue. If necessary, our certified experts will help you elect industrial instruments that will fully meet the needs of the operation procedure. More than 4,000 customers have already comprehended the high quality of the elements we transport and the dedication of the FAMAGA staff.
To define the value of Keyence IB-1500 and shipment time, you can fill in a special filling form on our website, give a list of desirable instruments by E-mail or call to the indicated phone numbers. We will be able to create the best commercial offer for you and present prompt shipment times to any urban place in the United Kingdom and any country in the globe.
Model | IB-1500 | |
Type | Panel mount | |
Main unit/Expansion unit | Main unit | |
Head compatibility | Yes | |
Display | Display resolution | 0.01 %, 0.1 %, 1 % (switchable) |
Display range | –99.999 to 99.999, –99.99 to 99.99, –99.9 to 99.9, –99 to 99 (switchable) | |
Digital display method | Dual 7-segment display, Upper level: 2-colour (green/red), 5 digits, Lower level: 5 green digits | |
Operation indicator | Judgment indicator: 2-colour (green/red) LED (HI, GO, LO), Bank indicator: Green LED x 4, Laser emission warning indicator: Green LED, Others: Green LED x 8, red LED x 3 | |
Analogue output voltage | ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100?*1 | |
Analogue current output | 4 to 20 mA Maximum load resistance 350 ?*1 | |
Control Input | Bank switch input, zero shift input | Non-voltage input*2 |
Control input | Zero-shift input | |
Laser emission stop input | ||
Timing input | ||
Reset input | ||
Adjust input | ||
Control output | Judgment output (check output) | Open collector (NPN/PNP switchable, N.O./N.C. switchable)*3 |
Power supply | Power consumption | 2,100 mW or less (at 30 V, 70 mA max.)*4 |
Rating | Power voltage | 10 to 30 VDC, including Ripple (P-P) 10 %, Class 2 or LPS |
Environmental resistance | Pollution degree | 2 |
Ambient temperature | -10 to +50 °C (No condensation or freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |
Material | Case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC | |
Weight | Approx. 170 g | |
*1 ±5 V, 1 to 5 V, 0 to 5 V, or 4 - 20 mA should be selected. *2 The four external input wires are assigned with desired inputs. Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less *3 Rated NPN open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 2 V or less *4 The power consumption with slave units installed is the total of each amplifier unit's power consumption. Example: When using one master unit (IB-1000) with two slave units (IB-1050) (1,950 mW x 1) + (1,950 mW x 2) = 5,850 mW |