We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence GT2-PA12L , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Burma, Mozambique, East Timor, Malta, Kiribati, Panama, Morocco, Turkey, Colombia, Croatia, Israel, Cape Verde, Lebanon, Haiti, Luxembourg, Gabon, Uzbekistan, Georgia, Nigeria, Saudi Arabia, Laos, Denmark, Macedonia, Cyprus, Ecuador, Japan, El Salvador, Bangladesh, Iran, Côte d\'Ivoire, Rwanda, Afghanistan, Lesotho, Costa Rica, Benin, Tunisia, Sweden, Bulgaria, Argentina, Hungary, Philippines, United Arab Emirates, Eswatini, Dominica, Congo.
We have been delivering Keyence items throughout the UK and anywhere in the world for over 10 years. All equipment and materials are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from key European manufacturers and a minimum trade margin, we give our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the items we supply and the professionalism of the FAMAGA employees.
To clarify the charge of Keyence GT2-PA12L and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.
Model | GT2-PA12L | |
Detection system | Scale Shot System II, absolute (no tracking errors) type | |
Measuring range | 12 mm | |
Resolution | 0.5 µm | |
Indicated accuracy | 2 µm (P-P)*1 | |
Measuring force | Downward mounting | 0.4 N*2 |
Side mounting | 0.35 N*2 | |
Upward mounting | 0.3 N*2 | |
Sampling cycle | 4 ms | |
Fluid used | Clean dry air | |
Operation indicator light | 2-color LED (red, green) | |
Environmental resistance | Enclosure rating | - |
Pressure resistance | 0.5 MPa | |
Applied pressure range | 0.05 MPa to 0.07 MPa | |
Ambient temperature | 0 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2 (IEC60068-2-27) | |
Materials | Main body | Main body case: SUS 303, Status indicator: PET, Sensor head-relay connector cable: PUR, Relay connector: PBT |
Contact | SUS304, SUS440C*3 | |
Sensor head cable | Optional (connect to relay connector) | |
Weight | Approx. 35 g (not including cable)*4 | |
*1 Value when the ambient temperature is 20 °C. *2 Representative value at the centre of the measuring range. Please note that the measuring force varies by the installation state of the dust boot. This is a representative value when using the GT2-PA12KL/PA12L with a pressure of 0.06 MPa. The measuring force varies depending on the air pressure used. For details, see table 1.No dust boots are used with the GT2-PA12KL/PA12L. *3 Contacts are available as options sold separately. *4 Including the relay connector. |