We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to get Keyence GT2-PA12 , in addition request other industrial equipment and constituent parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Poland, Uganda, Andorra, San Marino, Spain, Niger, East Timor, Burkina Faso, Paraguay, Syria, Mozambique, Sudan, Macedonia, Brunei, Haiti, Mauritius, Bahrain, Papua New Guinea, Finland, Fiji, Swaziland, Zambia, Côte d\'Ivoire, Austria, Liechtenstein, Madagascar, Tajikistan, Indonesia, Norway, Ecuador, Luxembourg, Slovenia, Sierra Leone, Moldova, Vietnam, Suriname, Hungary, Estonia, Cyprus, Panama, Denmark, Oman, Honduras, Afghanistan, Belarus.
We have been distributing Keyence items all over the UK and anywhere in the world for over 10 years. All apparatus and parts are provided with appropriate quality certificates, along with a guarantee from the official producer of products Keyence.
Thanks to the upfront deliveries from leading European manufacturers and a minimum trade margin, we offer our customers the most affordable prices for all products exhibited in our catalogue. If necessary, our qualified specialists will help you select industrial instruments that will fully meet the concerns of the mode of operation. More than 4,000 consumers have already praised the high quality of the goods we supply and the professionalism of the FAMAGA staff.
To clarify the value of Keyence GT2-PA12 and delivery times, you can fill in a special order form on our website, send a list of required instruments by E-mail or call to the indicated phone numbers. We will be able to compose the best commercial offer for you and provide short delivery times to any place in the UK and any country in the world.
Model | GT2-PA12 | |
Detection system | Scale Shot System II, absolute (no tracking errors) type | |
Measuring range | 12 mm | |
Resolution | 0.5 µm | |
Indicated accuracy | 2 µm (p-p)*1 | |
Measuring force | Downward mounting | 1.2 N*2 |
Side mounting | 1.15 N*2 | |
Upward mounting | 1.1 N*2 | |
Sampling cycle | 4 ms | |
Fluid used | Clean dry air | |
Operation indicator light | 2-colour LED (red, green) | |
Environmental resistance | Enclosure rating | IP67 (IEC) |
Pressure resistance | 0.5 MPa | |
Applied pressure range | 0.24 MPa to 0.26 MPa | |
Ambient temperature | 0 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2 (IEC60068-2-27) | |
Materials | Main body | Main body case: SUS 303, Status indicator: PET, Sensor head-relay connector cable: PUR, Relay connector: PBT, Spindle: SUS430 (Fluorine coating) |
Contact | SUS304, SUS440C*3 | |
Sensor head cable | Optional (connect to relay connector) | |
Weight | Approx. 35 g (not including cable)*4 | |
*1 Value when the ambient temperature is 20 °C. *2 Representative value at the centre of the measuring range. Please note that the measuring force varies by the installation state of the dust boot. This is a representative value when using the GT2-PA12K/PA12 with a pressure of 0.25 MPa. The measuring force varies depending on the air pressure used. For details, see table 1. No dust boots are used with the GT2-PA12K/PA12. *3 Contacts are available as options sold separately. *4 Including the relay connector. |