Mounting bracket PX-10P Keyence
Mounting bracket PX-10P Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence PX-10P

Manufacturer

Keyence

Country

Japan

Name

PX-10P

Type

Mounting bracket

Description

Sensor

Stock availability:

On request

213.33 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications PX-10P

If you want to buy Keyence PX-10P , as well as request other industrial equipment and replacement parts for its repair, please contact FAMAGA .

We have been delivering Keyence goods all over the UK and anywhere in the world for over 10 years. All instruments and components are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.

Thanks to the direct deliveries from key European manufacturers and a minimum trade margin, we give our customers the most reasonable prices for all products displayed in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we deliver and the professionalism of the FAMAGA employees.

To clarify the price of Keyence PX-10P and delivery terms, you can complete a special filling form on our website, send a list of essential equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the United Kingdom and any country in the world.

Features PX-10P

Amplifier Unit, Cable Type, PNP
Model PX-10P
Type Cable type
Output PNP
Response time 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)
Output selection LIGHT-ON/DARK-ON
Indicator lamp - Operation indicator:Red LED x 2, DSC orange LED x 1 - Dual digital monitor:Dual 7-segment display [Preset value (4-digit green LED) and current value (4-digit red LED) illuminated together, current value range:0 to 65504, excess gain:0 P to 999 P] - Hold function:Possible to display both peak and bottom hold values. Selectable from 5 variations. - Bar LED monitor [Excess gain displayed (85% to 115% in 7 steps)] - Scaling display
Detection mode Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor]
Shift function Variable between –1999 and 9999
Timer function Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot Timer duration selectable:1 ms to 9999 ms Maximum error against the setting value:10% max.
Control output PNP open-collector 30 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max.
External input Input time 2 ms (ON)/20 ms (OFF) min.
Interference prevention Up to 4 units (in all power modes)*1
Rating Power voltage 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2
Power consumption Standard mode:50 mA max. at 24 V/55 mA max. at 12 V Power saving mode:40 mA max. at 24 V/45 mA max. at 12 V
Environmental resistance Enclosure rating IEC: IP67/JEM: IP67/NEMA: 4X
Ambient temperature -10 to +55 °C (No freezing)*3
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Case material Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR
Weight Approx. 100 g (Including cable)
*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected somewhat when using multiple units installed adjacent to each other. Fine-tune the sensitivity (increase the setting) for adjacent layouts. *2 Use a 24 VDC power voltage when using a head light transmitting cable of 3 m or more (PX-H71/H71TZ) or 10 m or more (PX-H72). *3 When using multiple units connected adjacently, the ambient temperature varies with the conditions below. 2 to 4 Units: -10 to +50 °C, 5 to 17 Units: -10 to +45 °C.