We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence PS-N12P , as well as order other industrial equipment and replacement parts for its adjust, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Paraguay, Lithuania, Bosnia and Herzegovina, Syria, Iran, Uzbekistan, Morocco, Austria, Sudan, East Timor, Serbia, South Africa, Belarus, Antigua and Barbuda, Rwanda, Eritrea, Turkmenistan, Japan, Bangladesh, Tanzania, Kuwait, Guinea, South Korea, Cape Verde, Angola, Luxembourg, Benin, Zambia, Dominican Republic, Liechtenstein, Bulgaria, Nigeria, Belgium, Côte d\'Ivoire, Eswatini, Tunisia, Sri Lanka, Burkina Faso, The Bahamas, Ukraine, Azerbaijan.
We have been delivering Keyence units all over the UK and anywhere in the world for over 9 years. All equipment and parts are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.
Thanks to the direct deliveries from prominent European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we supply and the professionalism of the FAMAGA employees.
To clarify the value of Keyence PS-N12P and delivery terms, you can fill in a special filling form on our website, give a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any place in the UK and any country in the world.
Model | PS-N12P | |
Type | Cable | |
Output | PNP | |
Main unit/Expansion unit | Expansion unit | |
I/O | Control outputs | 1 output |
External input | None | |
Response time | 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max. | |
Control output | PNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, residual voltage 1.2 V max. (when the output current is 10 mA or less)/2.2 V max. (when the output current is 10 to 100 mA) | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*1 | |
Unit expansion | Up to 17 main units can be connected | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | 4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled) | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 860 mW or less (at 30 V. 30 mA max. at 24 V, 35 mA max. at 12 V) Eco on mode (ALL): 750 mW or less (at 30 V. 26 mA max. at 24 V, 28 mA max. at 12 V) Eco Full mode: 540 mW or less (at 30 V. 19 mA max. at 24 V, 21 mA max. at 12 V) | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*2 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Case | Main unit and cover material: Polycarbonate |
Cable | PVC | |
Weight | Approx. 65 g | |
*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected. *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a uni t . One or two more units connected: -20 to +55 °C , 3 to 10 more units connected: -20 to +50 °C, 11 to 16 more units connected: -20 to +45 °C . |