We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence CZ-V22P , as well as order other industrial equipment and replacement parts for its adjust, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Georgia, Gabon, Tunisia, Monaco, New Zealand, Moldova, Czech Republic, Syria, Liechtenstein, San Marino, East Timor, Belize, Mauritius, Guatemala, Pakistan, Sri Lanka, Tajikistan, Sudan, Angola, Qatar, Venezuela, Costa Rica, Barbados, Cuba, Paraguay, Argentina, Dominican Republic, Sierra Leone, Burundi, Cape Verde, Guinea, Norway, Equatorial Guinea, Azerbaijan, Palestine, Antigua and Barbuda, South Korea, China, Belarus, Thailand.
We have been delivering Keyence units all over the UK and anywhere in the world for over 9 years. All equipment and parts are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.
Thanks to the direct deliveries from prominent European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we supply and the professionalism of the FAMAGA employees.
To clarify the value of Keyence CZ-V22P and delivery terms, you can fill in a special filling form on our website, give a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any place in the UK and any country in the world.
Model | CZ-V22P | |
Output | PNP output | |
Main unit/Expansion unit | Expansionunit | |
Response time | 8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED) | |
Control output | PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1 | |
Protection circuit | Reverse-polarity protection, overcurrent protection, surge absorber | |
External calibration input | No-voltage input, input time: 20 ms or more | |
External shift input | ||
Timer function | Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively) | |
Unit expansion | Up to 3 units (4 units total including the main unit)*2 | |
Rating | Power voltage | 24 VDC, Ripple (P-P) 10 % or less |
Power consumption | Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less) | |
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing)*3 |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |
Material | Housing, cover: Polycarbonate | |
Weight | Approx. 100 g | |
*1 20 mA max. when several units are connected. *2 The FS-V20 Series expansion unit cannot be connected to the CZ-V20 Series main unit. When using a combination of expansion units, connect the CZ-V20 Series expansion unit to the FS-V20 Series main unit. Also, if using multiple expansion units, make sure to connect the CZ-V20 Series to right side of the FS-V20 Series. *3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA. When 1 or 2 units are connected: -10 to +50 °C When 3 units are connected: -10 to +45 °C |