We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to get Keyence LV-11SB , along with demand other industrial equipment and spare parts for its refit, please connect FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Zimbabwe, Egypt, Finland, Bangladesh, Russia, Eritrea, Djibouti, Turkmenistan, Gabon, East Timor, Sudan, Eswatini, Bhutan, Sierra Leone, Liberia, Luxembourg, Denmark, Tajikistan, Mauritania, Jamaica, Spain, Cameroon, New Zealand, Belarus, Barbados, Nigeria, Madagascar, Tonga, Indonesia, Slovenia, Moldova, Cyprus, South Korea, Honduras, Liechtenstein, El Salvador, Bulgaria, Niger.
We have been distributing Keyence items all over the UK and anywhere in the globe for over 11 years. All machinery and constituents are provided with appropriate quality certificates, with a guarantee from the official manufacturer of products Keyence.
Thanks to the prompt supplies from global European manufacturers and a low trade margin, we give our customers the most fair costs for all products presented in our catalogue. If necessary, our proficient consultants will help you elect industrial machinery that will fully meet the necessities of the manufacturing process. More than 4,000 customers have already praised the high quality of the goods we deliver and the professionalism of the FAMAGA team members.
To clarify the price of Keyence LV-11SB and shipment time, you can fill in a special filling form on our website, give a list of necessary instruments by E-mail or call to the indicated phone numbers. We will be able to create the best commercial offer for you and present optimal distribution times to any urban place in Great Britain and any country in the earth.
Model | LV-11SB*1 | ||
Type | Main unit | ||
Output | NPN | ||
Control output | NPN open-collector x 2 ch 40 VDC max. 100 mA max. per output | ||
Response time | ExceptLV-S31 | ULTRA | 4 ms |
SUPER | 2 ms | ||
TURBO | 500 µs | ||
FINE | 250 µs | ||
HSP | 80 µs | ||
LV-S31standard mode | 500 µs | ||
LV-S31standard mode | SPED2 | 2 ms | |
SPED3 | 8 ms | ||
SPED4 | 32 ms | ||
LV-S31High-speed mode | 250 µs | ||
Control input | Light emission stop input, external calibration, set value bank selection input, or shift input | ||
Number of interference prevention units | ULTRA | 4*2 | |
SUPER | |||
TURBO | 2*2 | ||
FINE | |||
HSP | 0*2 | ||
Unit expansion | Up to 16 expansion units can be installed (17 units including the main unit)*3 | ||
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*4 | |
Power consumption | Normal | 1.7 W max. (70 mA max. for 24 V) | |
Ratings | Eco-Half Eco-All | 1.55 W max. (65 mA max. for 24 V) | |
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing)*5 | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | ||
Material | Main unit | Main body, cover: Polycarbonate | |
Weight | Approx. 80 g (including 2 m cable) | ||
*1 LV-S62 and LV-S63 can ONLY be used with amplifiers ending with B or BP. *2 Numbers for the LV-S31 are four in standard mode and two in high-speed mode. *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55?C (14 to 131?F) 3 to 10 units connected: -10 to +50?C (14 to 122?F) 11 to 16 units connected: -10 to +45?C (14 to 113?F) *4 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max. *5 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C |