We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence LV-11SAP , as well as request other industrial equipment and constituent parts for its refit, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Seychelles, Botswana, Cyprus, Libya, Kenya, Georgia, Bahamas, Peru, Angola, Mali, Cuba, Swaziland, Bosnia and Herzegovina, Denmark, Kuwait, Bangladesh, Comoros, New Zealand, Cape Verde, Equatorial Guinea, Algeria, Iraq, Afghanistan, Japan, Central African Republic, Argentina, Sri Lanka, Bulgaria, United Arab Emirates, Malaysia, Rwanda, Turkey, South Africa, Thailand, Mauritius, Kazakhstan, Brunei, Costa Rica.
We have been distributing Keyence goods all over the UK and anywhere in the globe for over 9 years. All machinery and parts are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.
Thanks to the prompt supplies from global European manufacturers and a nominal trade margin, we propose our customers the most reasonable prices for all products displayed in our catalogue. If necessary, our professional managers will help you select industrial machinery that will fully meet the requirements of the mode of operation. More than 4,000 buyers have already appreciated the high quality of the elements we deliver and the competence of the FAMAGA workers.
To clarify the price of Keyence LV-11SAP and delivery times, you can fill in a special order form on our website, dispatch a list of necessary machinery by E-mail or call to the specified phone numbers. We will be able to make the best commercial offer for you and prepare prompt shipment times to any place in the United Kingdom and any country in the globe.
Model | LV-11SAP | ||
Type | Main unit | ||
Main unit/Expansion unit | |||
Applicable model | LV-S61/S41/S41L/S31/S71/S72 | ||
Control output | PNP open-collector ? 2 channels, 30 VDC maximum, 100 mA or less per output | ||
Response time | ExceptLV-S31 | ULTRA | 4 ms |
SUPER | 2 ms | ||
TURBO | 500 µs | ||
FINE | 250 µs | ||
HSP | 80 µs | ||
LV-S31standard mode | 500 µs | ||
LV-S31standard mode | SPED2 | 2 ms | |
SPED3 | 8 ms | ||
SPED4 | 32 ms | ||
LV-S31High-speed mode | 250 µs | ||
Control input | Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input | ||
Number of interference prevention units | ULTRA | 4 | |
SUPER | |||
TURBO | 2 | ||
FINE | |||
HSP | 0 | ||
Unit expansion | Up to 16 units (17 units total including the main unit)*1 | ||
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2 | |
Power consumption | Normal | 1.5 W or less (62.5 mA or less at 24 V) | |
Ratings | Eco-Half Eco-All | 1.35 W or less (57.3 mA or less at 24 V) | |
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing)*3 | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | ||
Material | Main unit | Main body, cover: Polycarbonate | |
Weight | Approx. 80 g (including 2 m cable) | ||
*1 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is *2 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max. *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C |