Mounting bracket LV-N11P Keyence
Mounting bracket LV-N11P Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence LV-N11P

Manufacturer

Keyence

Country

Japan

Name

LV-N11P

Type

Mounting bracket

Description

Plus Verstärker, LASER PHOTOELEKTRISCHER SENSOR

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LV-N11P

If you want to buy Keyence LV-N11P , as well as request other industrial equipment and constituent parts for its repair, please call FAMAGA .

We have been distributing Keyence units all over the UK and anywhere in the globe for over 11 years. All equipment and constituents are provided with appropriate quality certificates, along with a guarantee from the official creator of products Keyence.

Thanks to the direct deliveries from leading European manufacturers and a low trade margin, we recommend our customers the most fair costs for all products presented in our catalogue. If necessary, our proficient consultants will help you elect industrial equipment that will fully meet the requirements of the operation procedure. More than 4,000 consumers have already appreciated the high quality of the products we deliver and the professionalism of the FAMAGA team members.

To clarify the charge of Keyence LV-N11P and shipment time, you can fill in a special order form on our website, dispatch a list of essential equipment by E-mail or call to the specified phone numbers. We will be able to create the best commercial offer for you and present optimal distribution times to any urban place in the UK and any country in the world.

Features LV-N11P

Amplifier, Cable, Main unit, PNP
Model LV-N11P
Type 2 output
Output PNP
Cable/connector Cable
Main/Expansion unit Main unit
I/O Control outputs 2 output
External input 1 input
Monitor output None
Response time 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1
Output selection LIGHT-ON/DARK-ON (switch-selectable)
Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.
Control outputs PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less
Monitor output -
External input Input time 2 ms (ON)/20 ms (OFF) or more*2
Multiple connections to expansion units Up to 17 units can be connected in total (two-output type is treated as two units)
Protection circuit Reverse polarity protection, Over-current protection, Surge absorber
Number of interference prevention units Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3
Case size H 32.6 mm ? W 9.8 mm ? L 78.7 mm
Rating Power voltage 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS
Power consumption Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*4 Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*4 Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V) *5
Environmental resistance Ambient temperature -20 to +55 °C (No freezing)*6
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Material Cable PVC
Case Main unit and cover material: Polycarbonate
Weight Approx. 75 g
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units.