We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence LV-N12CP , as well as demand other industrial equipment and spare parts for its mend, please connect FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Canada, Switzerland, Morocco, Romania, San Marino, Guyana, Chad, The Gambia, Andorra, Guatemala, Japan, Qatar, Ethiopia, Mexico, Mozambique, Comoros, Lithuania, Malaysia, Hungary, Kazakhstan, Nicaragua, Cyprus, Czech Republic, Dominica, Haiti, Slovakia, Grenada, Peru, Uganda, Kuwait, Indonesia, Estonia, Armenia, Zambia, Monaco, Spain, Greece, Oman, Gabon, Jamaica, Kiribati, Iraq, Philippines, Luxembourg, Algeria, Côte d\'Ivoire.
We have been delivering Keyence goods all around the UK and anywhere in the globe for over 11 years. All machinery and constituents are provided with appropriate quality certificates, together with a guarantee from the official creator of products Keyence.
Thanks to the shortest shipment from leading European manufacturers and a minimal trade margin, we offer our customers the most affordable prices for all products exposed in our catalogue. If necessary, our professional managers will help you select industrial machinery that will fully meet the requirements of the mode of operation. More than 4,000 buyers have already appreciated the high quality of the units we transport and the competence of the FAMAGA team members.
To define the value of Keyence LV-N12CP and delivery terms, you can complete a special filling form on our website, send a list of necessary machinery by E-mail or call to the specified phone numbers. We will be able to make the best commercial offer for you and give prompt distribution times to any place in the UK and any country in the planet.
Model | LV-N12CP | |
Type | 1 output | |
Output | PNP | |
Cable/connector | M8 connector | |
Main/Expansion unit | Expansion unit | |
I/O | Control outputs | 1 output |
External input | 1 input | |
Monitor output | None | |
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. | |
Control outputs | PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Multiple connections to expansion units | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*4 Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*4 Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V) *5 | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 20 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |