Keyence LR-ZB240CB

Manufacturer

Keyence

Country

Japan

Name

LR-ZB240CB

Type

Mounting bracket

Description

M18 threaded mount w/ M12 connector type, 240 mm

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LR-ZB240CB

If you want to get Keyence LR-ZB240CB , along with demand other industrial equipment and replacement parts for its mend, please approach FAMAGA .

We have been supplying Keyence elements all over the United Kingdom and anywhere in the planet for over 11 years. All machinery and components are provided with appropriate quality certificates, as well as a guarantee from the official creator of products Keyence.

Thanks to the upfront deliveries from major European manufacturers and a nominal trade margin, we propose our customers the most affordable prices for all products exhibited in our catalogue. If necessary, our proficient consultants will help you pick industrial equipment that will fully meet the needs of the operation procedure. More than 4,000 customers have already comprehended the high quality of the products we bring and the dedication of the FAMAGA team members.

To clear up the charge of Keyence LR-ZB240CB and delivery terms, you can complete a special order form on our website, give a list of required equipment by E-mail or call to the indicated phone numbers. We will be able to create the best commercial offer for you and present optimal distribution times to any urban place in Great Britain and any country in the earth.

Features LR-ZB240CB

M18 threaded mount w/ M12 connector type, 240 mm
Model LR-ZB240CB
Type Distance based laser sensor
Shape M18 Threaded mount
Output Bipolar (NPN+PNP)
Cable connection M12 connector, 4-pin
Detectable distance 25 to 240 mm (215 to 0)*1
Standard detectable deviation 25 to 170 mm: 9 mm 170 to 240 mm: 25 mm
Display resolution 1 to 3 (1 to 3 mm)
Spot diameter Approx. 2.4 ? 1.2 mm at 240 mm
Response time 1.5 ms / 10 ms / 50 ms selectable
Light source Type Red laser (660 nm)
Laser class Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*2)
Function Indicator 3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green)
Timer OFF/ON delay/OFF delay/One-shot
Rating Power voltage 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Power consumption 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)
Specifications Control output NPN+PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA
Protection circuit Protection against reverse power connection, output overcurrent, output surge, reverse output connection
Output operation Light-ON / Dark-ON selectable
External input None
Environmental resistance Enclosure rating IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3
Insulation resistance 20 M? or more (500 VDC)
Ambient light Incandescent lamp: 2,000 lux or less Sunlight: 4,000 lux or less*4
Ambient temperature -10 to +50 °C
Storage temperature -25 to +75 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Withstand voltage 1,000 VAC, 50/60 Hz, 1 min
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 1,000 m/s2, 6 times in each of the X, Y, and Z directions
Material Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM, Nut: SUS316L, Lock washer: SUS304
Accessories Instruction Manual, Certification/Identification label (FDA)
Weight Approx. 75 g
*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds '-99', '-FF' is displayed. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 Have passed resistance tests with cleaning agents from multiple manufactures. *4 When the response time is 10 ms