Manufacturer
Keyence
Country
Japan
Name
LR-ZB100CP
Type
Mounting bracket
Description
Sensor Standalone Laser Sensor, 100mm, 4Pin, M8, PNP
Stock availability:
On request
If you want to buy Keyence LR-ZB100CP , as well as demand other industrial equipment and spare parts for its fix, please approach FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Burma, Oman, Brunei, Philippines, Tonga, Slovakia, Mauritania, Gabon, Monaco, Lesotho, San Marino, Andorra, Kuwait, Haiti, South Sudan, Finland, Papua New Guinea, Colombia, Guatemala, Côte d\'Ivoire, Laos, Grenada, Malaysia, Mozambique, Bhutan, Senegal, Zambia, Yemen, Peru, Tunisia, Hungary, New Zealand, Burundi, Denmark, Angola, Lithuania, South Korea, El Salvador, Belgium, Armenia, Bulgaria, Bahrain, South Africa, Jamaica, Algeria, Serbia, Indonesia, Estonia.
We have been supplying Keyence items throughout the United Kingdom and anywhere in the world for over 11 years. All equipment and components are provided with appropriate quality certificates, with a guarantee from the official manufacturer of products Keyence.
Thanks to the direct deliveries from global European manufacturers and a minimal trade margin, we offer our customers the most fair costs for all products exhibited in our catalogue. If necessary, our qualified specialists will help you choose industrial instruments that will fully meet the requirements of the mode of operation. More than 4,000 customers have already comprehended the high quality of the goods we supply and the professionalism of the FAMAGA workers.
To clear up the cost of Keyence LR-ZB100CP and delivery times, you can fill out a special order form on our website, send a list of essential equipment by E-mail or call to the quoted phone numbers. We will be able to make the best sales offer for you and give optimal delivery times to any place in Great Britain and any country in the globe.
Model | LR-ZB100CP | |
Type | Distance based laser sensor | |
Shape | Rectangular | |
Output | PNP | |
Cable connection | M8 connector, 4-pin | |
Detectable distance | 35 to 100 mm (650 to 0)*1 | |
Standard detectable deviation | 35 to 50 mm: 1.5 mm 50 to 100 mm: 3 mm | |
Display resolution | 2 (0.2 mm) | |
Spot diameter | Approx. 2 ? 1 mm at 100 mm | |
Response time | 1.5 ms / 10 ms / 50 ms selectable | |
Light source | Type | Red laser (660 nm) |
Laser class | Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*2) | |
Function | Indicator | 3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) |
Timer | OFF/ON delay/OFF delay/One-shot | |
Rating | Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
Power consumption | 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12V) | |
Specifications | Control output | PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, reverse output connection | |
Output operation | Light-ON / Dark-ON selectable | |
External input | Input time calibration: 35 ms or more ON, 35 ms or more OFF Laser emission stop: 2 ms or more ON, 20 ms or more OFF Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less | |
Environmental resistance | Enclosure rating | IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |
Insulation resistance | 20 M? or more (500 VDC) | |
Ambient light | Incandescent lamp: 4,000 lux or less Sunlight: 8,000 lux or less*4 | |
Ambient temperature | -10 to +50 °C (No freezing) | |
Storage temperature | -25 to +75 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Withstand voltage | 1,000 VAC, 50/60 Hz, 1 min | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
Material | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM | |
Accessories | Instruction Manual, Certification/Identification label (FDA) | |
Weight | Approx. 55 g | |
*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds '-99', '-FF' is displayed. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 Have passed resistance tests with cleaning agents from multiple manufactures. *4 When the response time is 10 ms |