We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to purchase Keyence LR-TB5000 , along with require other industrial equipment and constituent parts for its repair, please connect FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Guyana, Mauritius, Lithuania, Ukraine, The Bahamas, Thailand, Poland, Algeria, Mali, Congo, Guinea-Bissau, Israel, Greece, Gabon, Austria, Tanzania, Sierra Leone, Bosnia and Herzegovina, Zambia, China, Armenia, Tunisia, Libya, Cameroon, Madagascar, Fiji, Qatar, Tajikistan, Cambodia, Kuwait, Rwanda, Hungary, Japan, Cape Verde, Belize, Suriname, Costa Rica, Czech Republic, Belgium, Liechtenstein, Laos, Ecuador, Malaysia, Philippines, Haiti, Angola, Kiribati.
We have been delivering Keyence elements throughout Great Britain and anywhere in the earth for over 10 years. All machinery and parts are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.
Thanks to the prompt supplies from leading European manufacturers and a minimal trade margin, we give our customers the most fair costs for all products exposed in our catalogue. If necessary, our professional managers will help you pick industrial machinery that will fully meet the requirements of the production process. More than 4,000 consumers have already appreciated the high quality of the elements we supply and the competence of the FAMAGA workers.
To define the value of Keyence LR-TB5000 and delivery terms, you can complete a special order form on our website, send a list of necessary machinery by E-mail or call to the mentioned phone numbers. We will be able to compose the best financial offer for you and prepare prompt distribution times to any urban place in the UK and any country in the globe.
Model | LR-TB5000 | |
Type | Cable | |
Detectable distance | 60 to 5000 mm*1 | |
Spot diameter | Variable (use a spot diameter of 40 mm or less) | |
Response time | 1 ms/10 ms/25 ms/100 ms/1000 ms selectable | |
Light source | Type | Red laser (660 nm) |
Laser class | Class 2 laser product (IEC60825-1,FDA (CDRH) Part1040.10*2) | |
Mutual interference prevention function | 4 units (when using the interference prevention function) | |
Timer | OFF/OFF delay/ON delay/One-shot | |
Power voltage | 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS | |
Current consumption | 50 mA or less (without load)*3 | |
I/O | Control output | NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, residual voltage: 2 V or less, N.O./N.C. selectable *4*5 |
External input | Switchable between transmission OFF, teaching, and reference surface update Short-circuit current: 1 mA or less for both NPN and PNP For the applied voltage, see the wiring diagrams (pages 2 and 3 in the instruction manual). For the input times, see the time charts (page 4 in the instruction manual).*3 | |
Analogue output | Current output/Voltage output selectable Current output: 4 to 20 mA with a max. load resistance of 500 ? Voltage output: 0 to 10 V with an external load resistance of 5 k? or more *4*5 | |
Protection circuit | Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient light | Incandescent lamp/Sunlight: 10,0000 lux or less | |
Ambient temperature | -20 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
Material | Case: Zinc die cast (Nickel chrome plating), Indicator cover and buttons: PES, Lens cover and display: PMMA (scratch-resistant coating specifications), Cable bushing: PBT, Cable: PVC | |
Accompanying items | Instruction manual, Laser warning and explanation labels | |
Weight | Approx. 200 g (Including cable) | |
*1 The range for displayable distance is from 50 to 5200. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 150 mA or less (with load) *4 You can select the I/O from the following combinations. Control output ? 2, control output + external input Control output + analogue output (LR-TB5000/TB5000C/TB5000CL only), External input + analogue output (LR-TB5000/TB5000C/TB5000CL only) (For details on the setting method, see the instruction manual.) *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office. |