We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to gain Keyence LR-TB2000C , along with require other industrial equipment and constituent parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Argentina, Algeria, Madagascar, Macedonia, South Korea, Bosnia and Herzegovina, Croatia, Angola, Saudi Arabia, Bolivia, Paraguay, Uganda, Cyprus, Yemen, Uzbekistan, Kyrgyzstan, Cuba, Burundi, Norway, Venezuela, Vietnam, Ukraine, Oman, Benin, New Zealand, Qatar, Israel, Japan, Bahrain, Ghana, Haiti, Niger, Kazakhstan, Turkmenistan, Bulgaria, Lebanon, Belize, Nigeria, Azerbaijan, Spain, Thailand, Kiribati, Sweden, Zambia, Dominican Republic, Antigua and Barbuda, Russia.
We have been delivering Keyence elements throughout Great Britain and anywhere in the world for over 11 years. All apparatus and components are provided with appropriate quality certificates, as well as a guarantee from the official producer of products Keyence.
Thanks to the upfront deliveries from key European manufacturers and a minimum trade margin, we suggest our customers the most reasonable prices for all products presented in our catalogue. If necessary, our proficient consultants will help you select industrial machinery that will fully meet the concerns of the manufacturing process. More than 4,000 clients have already comprehended the high quality of the items we bring and the professionalism of the FAMAGA employees.
To define the value of Keyence LR-TB2000C and delivery terms, you can fill in a special inquiry form on our website, send a list of desirable machinery by E-mail or call to the quoted phone numbers. We will be able to compose the best sales offer for you and provide optimal supply times to any city in Great Britain and any country in the world.
Model | LR-TB2000C | |
Type | Cable with connector M12 | |
Detectable distance | 60 to 2000 mm*1 | |
Spot diameter | Approx. 4 mm | |
Response time | 1 ms/10 ms/25 ms/100 ms/1000 ms selectable | |
Light source | Type | Red laser (660 nm) |
Laser class | Class 2 laser product (IEC60825-1,FDA (CDRH) Part1040.10*2) | |
Mutual interference prevention function | 4 units (when using the interference prevention function) | |
Timer | OFF/OFF delay/ON delay/One-shot | |
Power voltage | 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS | |
Current consumption | 45 mA or less (without load)*3 | |
I/O | Control output | NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, residual voltage: 2 V or less, N.O./N.C. selectable *4*5 |
External input | Switchable between transmission OFF, teaching, and reference surface update Short-circuit current: 1 mA or less for both NPN and PNP For the applied voltage, see the wiring diagrams (pages 2 and 3 in the instruction manual). For the input times, see the time charts (page 4 in the instruction manual).*6 | |
Analogue output | - | |
Protection circuit | Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient light | Incandescent lamp/Sunlight: 10,0000 lux or less | |
Ambient temperature | -20 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
Material | Case: Zinc die cast (Nickel chrome plating), Indicator cover and buttons: PES, Lens cover and display: PMMA (scratch-resistant coating specifications), Cable bushing: PBT, Cable: PVC, M12 connector: TPE, PBT, Nickel-plated brass | |
Accompanying items | Instruction manual, Laser warning and explanation labels | |
Weight | Approx. 85 g | |
*1 The range for displayable distance is from 50 to 2200. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 145 mA or less (with load) *4 You can select the I/O from the following combinations. Control output ? 2, control output + external input Control output + analogue output (LR-TB5000/TB5000C/TB5000CL only), External input + analogue output (LR-TB5000/TB5000C/TB5000CL only) (For details on the setting method, see the instruction manual.) *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office. *6 You can select the I/O from the following combinations. Control output ? 2, control output + external input, IO-Link (For details on the setting method, see page 3 of the instruction manual.) |