We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to get Keyence IX-360 , additionally request other industrial equipment and constituent parts for its repair, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Kyrgyzstan, Ethiopia, Ukraine, Eritrea, Malta, Greece, Indonesia, Australia, Zambia, Philippines, India, Armenia, Dominica, The Gambia, Togo, Mauritania, El Salvador, Niger, Liberia, Moldova, Jamaica, Algeria, Mozambique, Saudi Arabia, Yemen, Macedonia, New Zealand, Serbia, Suriname, Nicaragua, Egypt, Finland, Lebanon, Iraq, Bahrain, Iran, Cambodia, Lesotho, Swaziland, Monaco, Thailand, Czech Republic, Tonga, Senegal, Japan, Slovakia.
We have been shipping,conveying Keyence items all over Britain and anywhere in the planet for over 11 years. All equipment and components are provided with appropriate quality certificates, with a guarantee from the official creator of products Keyence.
Thanks to the upfront deliveries from leading European manufacturers and a low trade margin, we suggest our customers the most affordable prices for all products presented in our catalogue. If necessary, our certified experts will help you elect industrial machinery that will fully meet the concerns of the operation procedure. More than 4,000 customers have already appreciated the high quality of the products we transport and the dedication of the FAMAGA team members.
To illuminate the value of Keyence IX-360 and shipment time, you can fill out a special order form on our website, give a list of desirable machinery by E-mail or call to the specified phone numbers. We will be able to create the best commercial offer for you and provide optimal shipment times to any urban place in Great Britain and any country in the planet.
Model | IX-360 | |
Reference distance | 360 mm | |
Measuring distance | 280 to 440 mm | |
Detection area | Scan mode | Measuring distance of 280 mm: 66.0 ? 49.5 mm (min.) Measuring distance of 360 mm: 84.0 ? 63.0 mm (min.) Measuring distance of 440 mm: 102.0 ? 76.5 mm (X direction) ? (Y direction) *1 |
Line mode | Measuring distance of 280 mm: 66.0 mm (min.) Measuring distance of 360 mm: 84.0 mm (min.) Measuring distance of 440 mm: 102.0 mm (X direction) *1 | |
Laser Light source | Light source | 660 nm (visible light) wavelength red semiconductor laser |
Laser class | Class II laser product (FDA [CDRH] part 1040.10), Class 2 laser product (IEC 60825-1: 2014) | |
Output | 0.95 mW (FDA (CDRH) Part 1040.10), 1.6 mW (IEC 60825-1: 2014) | |
Minimum detectable object size | Scan mode | o1.8 mm*2 |
Line mode | 1.8 mm ? 1.8 mm*2 | |
Repeatability | 150 µm*3 | |
Estimated detection | (Estimated detection: When measuring the height between two points, the minimum step difference is as follows. IX-055: 100 µm / IX-080: 200 µm / IX-150: 500 µm / IX-360: 1000 µm) *3 | |
Sampling cycle | Scan mode | 120 ms (min.) (typical) |
Line mode | 6 ms / 11 ms (selectable) | |
Image receiving element | Monochrome CMOS image sensor | |
Image capture lighting | Light source | Red LED |
Lighting method | Pulse lighting | |
Temperature characteristics | 0.08% of F.S./°C*4 | |
Environmental resistance | Enclosure rating | IP67 |
Ambient light | Incandescent lamp, 5000 lux or less*5 | |
Operating ambient temperature | 0 to +45°C (No freezing) *6 | |
Operating ambient humidity | 35 to 85% RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the 3 directions | |
Material | Main unit case: Zinc die-casting / Front cover: Glass, acrylic (hard coat) / Operation indicator cover: TPU / Connector ring: PBT / Connector Zinc die-casting | |
Weight | Approx. 190 g | |
*1 X: Long-side direction of laser, Y: Short-side direction of laser *2 With a correctly attached reference distance. When measuring using the height tool, measurement point min., and no position adjustment in scan mode. When measuring using the height tool, tool window size min., and no position adjustment in line mode. *3 When measuring at the centre of the field of view in scan mode using the “Max.” measurement point of a KEYENCE reference target (white diffuser) at the reference distance. *4 At the reference distance from the target. The F.S. for each model are as follows. IX-055: ±10 mm, IX-080: ±18 mm, IX-150: ±50 mm, IX-360: ±80 mm *5 Using the default settings with a laser light source as the target. *6 With metal mounting. |