We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to purchase Keyence IX-1050 , in addition request other industrial equipment and spare parts for its adjust, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Botswana, Switzerland, East Timor, Liechtenstein, Georgia, Romania, Uzbekistan, United Arab Emirates, Eritrea, Namibia, Barbados, Ukraine, Sweden, Benin, Zambia, Guinea-Bissau, Cape Verde, Kazakhstan, Costa Rica, Kuwait, Rwanda, Equatorial Guinea, Nigeria, Paraguay, Israel, Antigua and Barbuda, Spain, Afghanistan, Cameroon, Ecuador, Sierra Leone, Togo, Cyprus, Kiribati, The Bahamas, Venezuela, Eswatini, China, Burundi, Azerbaijan, Albania, Guyana, Bulgaria, Philippines, Serbia, Tajikistan.
We have been shipping,conveying Keyence items all over the United Kingdom and anywhere in the planet for over 10 years. All equipment and components are provided with appropriate quality certificates, with a guarantee from the official manufacturer of products Keyence.
Thanks to the prompt supplies from major European manufacturers and a low trade margin, we suggest our customers the most affordable prices for all products presented in our catalogue. If necessary, our certified experts will help you elect industrial instruments that will fully meet the needs of the operation procedure. More than 4,000 customers have already appreciated the high quality of the products we transport and the dedication of the FAMAGA staff.
To define the value of Keyence IX-1050 and delivery times, you can fill in a special filling form on our website, dispatch a list of desirable instruments by E-mail or call to the indicated phone numbers. We will be able to create the best commercial offer for you and provide optimal shipment times to any city in the United Kingdom and any country in the globe.
Model | IX-1050 | |
Main unit / expansion unit | Expansion unit | |
Display | Min. display unit | 10 µm*1 |
Display range | ±999.99 to ±999 mm (with 4 selectable steps)*1 | |
Tools | Scan mode | Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2 |
Line mode | Height (Ave./Max./Min.), Height difference (Ave./Max./Min.), Height difference calculation, Thickness calculation, Position adjustment, Tilt correction (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2 | |
Other functions | Common | ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgement conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security |
Scan mode | Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range | |
Line mode | Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.) | |
Input | Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) | |
Input | Number of inputs | 8 (IN1 to IN8) |
Function | IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgement value only) Reset (judgement value and error) | |
Output | Open collector output, NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less | |
Output | Number of outputs | 10 (OUT1 to OUT10) |
Function | Enable by assigning the optional functions Assignable functions: Total judgement result (All OK, Any OK/NG), run, busy, error, position adjustment result, tilt correction result, Monochromatic detection / Height detection tool result (OK/NG), Height / height difference / Max./Min. / calculation tool result (OK/NG/HIGH/LO), Alarm | |
Analogue voltage output | Not available | |
Analogue current output | ||
Number of programs | 32 | |
Statistical information | Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1*3 | |
Detection history | Saved history | 100*4 |
Save conditions | Selectable from NG only / All*4 | |
Ethernet | Standard | Not available |
Connector | ||
Interface compatibility | CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT? / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*5 | |
Number of connectible units | Main units: 1, Expansion units: 1, Communication units (DL): 1 | |
Ratings | Power voltage | Supplied from main unit |
Current consumption | Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *6 | |
Environmental resistance | Operating ambient temperature | 0 to +50°C (No freezing) |
Operating ambient humidity | 35 to 85% RH (No condensation) | |
Material | Main unit case: PC / Power connector: PA, POM / Analogue output connector: PA, POM / I/O connector: PA / Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminium / Main unit rear DIN rail fixing tab: POM / Nameplate: PC | |
Weight | Approx. 190 g | |
*1 For displaying on an IX Series control panel or PC software. *2 Configurable for each program. *3 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set. *4 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software. *5 When a DL Series device is used. Contact KEYENCE for information on other interfaces. *6 Includes a DL Series communication unit. |