We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to purchase Keyence IX-1000 , in addition order other industrial equipment and replacement parts for its adjust, please call FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Brazil, Israel, Guatemala, Russia, Morocco, Georgia, Burkina Faso, India, Gambia, Central African Republic, Eswatini, Côte d\'Ivoire, Niger, Iraq, Barbados, Nicaragua, Lesotho, Serbia, South Africa, South Sudan, Brunei, Belarus, Guyana, Sudan, Myanmar, Mauritius, Armenia, Vietnam, Spain, Peru, Uganda, Uzbekistan, Gabon, Tonga, Mauritania, Bhutan, Senegal, Slovakia, Oman, Congo, Cyprus, Luxembourg, Iran, Afghanistan, Madagascar.
We have been shipping,conveying Keyence goods all over the UK and anywhere in the world for over 9 years. All apparatus and parts are provided with appropriate quality certificates, along with a guarantee from the official producer of products Keyence.
Thanks to the direct deliveries from major European manufacturers and a minimum trade margin, we propose our customers the most acceptable prices for all products displayed in our catalogue. If necessary, our professional managers will help you select industrial equipment that will fully meet the requirements of the manufacturing process. More than 4,000 buyers have already praised the high quality of the products we supply and the professionalism of the FAMAGA employees.
To illuminate the value of Keyence IX-1000 and delivery times, you can fill in a special order form on our website, give a list of necessary apparatus by E-mail or call to the specified phone numbers. We will be able to create the best trade offer for you and provide optimal delivery times to any urban place in Britain and any country in the globe.
Model | IX-1000 | |
Main unit / expansion unit | Main unit | |
Display | Min. display unit | 10 µm*1 |
Display range | ±999.99 to ±999 mm (with 4 selectable steps)*1 | |
Tools | Scan mode | Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2 |
Line mode | Height (Ave./Max./Min.), Height difference (Ave./Max./Min.), Height difference calculation, Thickness calculation, Position adjustment, Tilt correction (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2 | |
Other functions | Common | ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgement conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security |
Scan mode | Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range | |
Line mode | Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.) | |
Input | Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) | |
Input | Number of inputs | 8 (IN1 to IN8) |
Function | IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgement value only) Reset (judgement value and error) | |
Output | Open collector output, NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less | |
Output | Number of outputs | 10 (OUT1 to OUT10) |
Function | Enable by assigning the optional functions Assignable functions: Total judgement result (All OK, Any OK/NG), run, busy, error, position adjustment result, tilt correction result, Monochromatic detection / Height detection tool result (OK/NG), Height / height difference / Max./Min. / calculation tool result (OK/NG/HIGH/LO), Alarm | |
Analogue voltage output | ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 ?*3 | |
Analogue current output | 4 to 20 mA, max. load resistance: 350 ?*3 | |
Number of programs | 32 | |
Statistical information | Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1*4 | |
Detection history | Saved history | 100*5 |
Save conditions | Selectable from NG only / All*5 | |
Ethernet | Standard | 100BASE-TX/10BASE-T*6 |
Connector | RJ45 8-pin connector*6 | |
Interface compatibility | CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT? / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7 | |
Number of connectible units | Main units: 1, Expansion units: 1, Communication units (DL): 1 | |
Ratings | Power voltage | 24 VDC ±10% (including ripple) |
Current consumption | Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *8 | |
Environmental resistance | Operating ambient temperature | 0 to +50°C (No freezing) |
Operating ambient humidity | 35 to 85% RH (No condensation) | |
Material | Main unit case: PC / Power connector: PA, POM / Analogue output connector: PA, POM / I/O connector: PA / Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminium / Main unit rear DIN rail fixing tab: POM / Nameplate: PC | |
Weight | Approx. 210 g | |
*1 For displaying on an IX Series control panel or PC software. *2 Configurable for each program. *3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use. *4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set. *5 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software. *6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit. *7 When a DL Series device is used. Contact KEYENCE for information on other interfaces. *8 Includes a DL Series communication unit. |