We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence SL-C128F , as well as order other industrial equipment and constituent parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Japan, Romania, Bahamas, Zambia, East Timor, Burundi, Kiribati, Chad, Antigua and Barbuda, Laos, Qatar, Cuba, Paraguay, Guyana, Bahrain, Tanzania, Philippines, Tajikistan, Sweden, Yemen, Guinea-Bissau, Uganda, Uzbekistan, United Arab Emirates, Cambodia, Rwanda, Bangladesh, Pakistan, Haiti, El Salvador, Central African Republic, Turkey, Panama, Belize, Ukraine, Argentina, Sri Lanka, Egypt, Ghana, Slovenia, Austria, Bolivia, Congo.
We have been delivering Keyence elements all around the UK and anywhere in the world for over 11 years. All equipment and replacements are provided with appropriate quality certificates, together with a guarantee from the official creator of products Keyence.
Thanks to the direct deliveries from major European manufacturers and a minimum trade margin, we propose our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the elements we supply and the professionalism of the FAMAGA employees.
To clarify the expense of Keyence SL-C128F and shipment time, you can complete a special inquiry form on our website, dispatch a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any urban place in the UK and any country in the world.
Model | SL-C128F | ||
Effective aperture angle | Max. ±2.5 ° (when operating distance is at least 3 m) | ||
Response time | 15 ms *1 | ||
Light source | Infrared LED (850 nm) | ||
Operation mode | Turned on when light is being applied to all optical axes (excluding when the blanking function is used) | ||
Detection capability | o14 mm (when the blanking function is not used) | ||
No. of beam axes | 128 | ||
Detection zone | 1270 mm | ||
Protection area | 1294 mm | ||
Detectingdistance | 0.1 to 7 m | ||
Operating distance/Beam width | |||
Beam axis interval | 20 mm | ||
Lens diameter | o4mm | ||
OSSD output | Output type | 2 outputs each for PNP and NPN, Can be switched using the connection connector cable | |
Max. load current | 300 mA *2 | ||
OFF-state voltage | 2.5 V (with a cable length of 7 m) | ||
Leakage current | 100 µA maximum*3 | ||
Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
Load wiring resistance | 2.5 ? maximum*4 | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 Class A, FCC Part15 Class A | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (type 4 ESPE),IEC61496-2, EN61496-2, UL61496-2 (type 4 AOPD),UL508 | ||
Current consumption | Transmitter | 145 mA | |
Receiver | 114 mA | ||
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less | |
Environmental resistance | Enclosure rating | IP65 (IEC60529) | |
Ambient light | Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -10 to +60 °C (No condensation | ||
Operating relative humidity | 35 to 85 % RH (No condensation) | ||
Storage relative humidity | 35 to 95 % RH (No condensation) | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminum | |
Upper case/lower case | Zinc die-cast | ||
Front cover | Polycarbonate | ||
Weight | Transmitter | Approx 900 g | |
Receiver | Approx 995 g | ||
*1 OFF>ON return time is 125 ms. *2 Note the derating illustrated in the graph to the right when using PNP output. *3 This includes situations in which the SL-C Series is off and in which the power supply line is disconnected. *4 The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 ? or less to ensure that the SL-C Series operate correctly. If using the NPN output |