We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Keyence SL-C08L , as well as order other industrial equipment and replacement parts for its adjust, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Guinea, Papua New Guinea, Gambia, Comoros, Kyrgyzstan, Congo, Mauritius, Italy, Guyana, Bosnia and Herzegovina, Uganda, Zambia, Malta, Austria, Egypt, Pakistan, Norway, Kazakhstan, The Bahamas, Czech Republic, Cape Verde, Paraguay, China, Ghana, Burkina Faso, Dominican Republic, Azerbaijan, Qatar, Bangladesh, Madagascar, Thailand, Venezuela, South Korea, Rwanda, Ecuador, Uzbekistan, Cameroon, Turkmenistan, Ukraine, Vietnam, Turkey, Japan, Tajikistan.
We have been delivering Keyence units all over the UK and anywhere in the world for over 9 years. All equipment and parts are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.
Thanks to the direct deliveries from prominent European manufacturers and a minimum trade margin, we recommend our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the units we supply and the professionalism of the FAMAGA employees.
To clarify the value of Keyence SL-C08L and delivery terms, you can fill in a special filling form on our website, give a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any place in the UK and any country in the world.
Model | SL-C08L | ||
Effective aperture angle | Max. ±2.5 ° (when operating distance is at least 3 m) | ||
Response time | 15 ms *1 | ||
Light source | Infrared LED (850 nm) | ||
Operation mode | Turned on when light is being applied to all optical axes (excluding when the blanking function is used) | ||
Detection capability | o45 mm*2 | ||
No. of beam axes | 8 | ||
Detection zone | 280 mm | ||
Protection area | 365 mm | ||
Detectingdistance | 0.3 to 9 m | ||
Beam axis interval | 40 mm | ||
Lens diameter | o5mm | ||
OSSD output | Output type | 2 outputs each for PNP and NPN, Can be switched using the connection connector cable | |
Max. load current | 300 mA *3 | ||
OFF-state voltage | 2.5 V (with a cable length of 7 m) | ||
Leakage current | 100 µA maximum*4 | ||
Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
Load wiring resistance | 2.5 ? maximum*5 | ||
Approved standards | EMC | EMS | UL61496-1 |
EMI | FCC Part15 Class A | ||
Safety | UL61496-1 (type 4 ESPE), UL61496-2 (type 4 AOPD),UL508 | ||
Current consumption | Transmitter | 55 mA | |
Receiver | 67 mA | ||
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less | |
Environmental resistance | Enclosure rating | IP65 (IEC60529) | |
Ambient light | Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -10 to +60 °C (No condensation | ||
Operating relative humidity | 35 to 85 % RH (No condensation) | ||
Storage relative humidity | 35 to 95 % RH (No condensation) | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Weight | Transmitter | Approx 255 g | |
Receiver | Approx 280 g | ||
*1 OFF>ON return time is 125 ms. *2 If the SL-CL Series, which has a minimal detection object diameter of 45 mm, is used in conjunction with the SL-R12EX, the blanking function and muting function cannot be used. *3 Note the derating illustrated in the graph to the right when using PNP output. *4 This includes situations in which the SL-C Series is off and in which the power supply line is disconnected. *5 The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 ? or less to ensure that the SL-C Series operate correctly. If using the NPN output |