GL-R44H
Type
Mounting bracket
Description
Sicherheitslichtvorhang 25mm Auflösungsvermögen/44 Strahlachsen/905mm
Stock availability:
On request
If you want to get Keyence GL-R44H , additionally order other industrial equipment and replacement parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Zimbabwe, Mozambique, Paraguay, Myanmar, Mexico, Burkina Faso, Norway, Bulgaria, Algeria, United Arab Emirates, Malta, Mali, Morocco, Yemen, Egypt, Uganda, Swaziland, Sri Lanka, Denmark, Côte d\'Ivoire, Switzerland, Fiji, Libya, Argentina, Liberia, Cyprus, Estonia, Bangladesh, Saudi Arabia, Dominican Republic, Slovenia, Madagascar, Japan, Palestine, Mauritania, Kiribati, Indonesia, Colombia, Sudan, Grenada, Comoros, Kenya, South Africa, Barbados, Sweden, Iraq.
We have been distributing Keyence units throughout Britain and anywhere in the planet for over 9 years. All machinery and components are provided with appropriate quality certificates, together with a guarantee from the official producer of products Keyence.
Thanks to the upfront deliveries from global European manufacturers and a low trade margin, we recommend our customers the most fair costs for all products exposed in our catalogue. If necessary, our professional managers will help you elect industrial machinery that will fully meet the concerns of the production process. More than 4,000 customers have already comprehended the high quality of the goods we deliver and the professionalism of the FAMAGA team members.
To illuminate the charge of Keyence GL-R44H and delivery terms, you can complete a special filling form on our website, give a list of necessary machinery by E-mail or call to the mentioned phone numbers. We will be able to create the best commercial offer for you and present adequate supply times to any place in Great Britain and any country in the planet.
Model | GL-R44H | ||
Detection capability | o25 mm | ||
Beam axis spacing/Lens diameter | 20 mm / o5 | ||
Detecting distance | 0.2 to 15 m*1 | ||
Effective aperture angle | Max. ±2.5° (When operating distance is 3 m or more) | ||
Light source | Infrared LED (870 nm) | ||
Response time (OSSD) (ms) | Wire synchronisation, One-line or Optical synchronisation system (Channel 0) | ON>OFF | 9.2 |
OFF>ON | 52.6*2 | ||
All blocked>ON | 73.5*3 | ||
Optical synchronisation system (Channel A or B) | ON>OFF | 12.9 | |
OFF>ON | 58.2*2 | ||
All blocked>ON | 88.6*3 | ||
Detection mode | Turns on when no interruptions are present in the detection zone | ||
Synchronisation between the transmitter and receiver | Optical synchronisation or Wire synchronisation (Determined by wiring) | ||
Light interference prevention function | Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically | ||
Control output (OSSD output) | Output | 2 transistor outputs. (PNP or NPN is determined by the cable type) | |
Max. load current | 500 mA*4 | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
OFF state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
Leakage current | Max. 200 µA | ||
Max. capacitive load | 2.2 µF | ||
Load wiring resistance | Max. 2.5 ? | ||
Supplemental output (Non-safety-related output) | AUX | transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m) | |
Error output | |||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. | ||
External input | When using a PNP output cable | EDM input Wait input Reset input Muting input 1, 2 Override input | ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
When using an NPN output cable | ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) | ||
Rating | Power voltage | 24 VDC ±20%, ripple (P-P) 10% or less, Class 2 | |
Power supply | Current consumption (Max.) (mA) | Transmitter | 66 |
Receiver | 77 | ||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998 | ||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 15 to 85 % RH (No condensation) | ||
Storage relative humidity | 15 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminium | |
Upper case/lower case | Nylon (GF 30%) | ||
Front cover | Polycarbonate, SUS304 | ||
Weight | Transmitter | 1220 g | |
Receiver | |||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m. *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms. *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation, the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then determines the clear or blocked. *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA. |