Mounting bracket GL-R08H Keyence
Mounting bracket GL-R08H Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence GL-R08H

Manufacturer

Keyence

Country

Japan

Name

GL-R08H

Type

Mounting bracket

Description

Main Unit

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications GL-R08H

If you want to get Keyence GL-R08H , additionally order other industrial equipment and replacement parts for its adjust, please connect FAMAGA .

We have been delivering Keyence units throughout the United Kingdom and anywhere in the earth for over 9 years. All apparatus and materials are provided with appropriate quality certificates, as well as a guarantee from the official producer of products Keyence.

Thanks to the prompt supplies from leading European manufacturers and a minimal trade margin, we propose our customers the most reasonable prices for all products exposed in our catalogue. If necessary, our proficient consultants will help you elect industrial equipment that will fully meet the necessities of the production process. More than 4,000 consumers have already appreciated the high quality of the units we transport and the proficiency of the FAMAGA workers.

To clear up the expense of Keyence GL-R08H and delivery terms, you can fill in a special filling form on our website, give a list of necessary machinery by E-mail or call to the specified phone numbers. We will be able to create the best financial offer for you and present adequate delivery times to any place in the UK and any country in the globe.

Features GL-R08H

Main Unit, Hand-protection Type, 8 Optical Axes
Model GL-R08H
Detection capability o25 mm
Beam axis spacing/Lens diameter 20 mm / o5
Detecting distance 0.2 to 15 m*1
Effective aperture angle Max. ±2.5° (When operating distance is 3 m or more)
Light source Infrared LED (870 nm)
Response time (OSSD) (ms) Wire synchronisation, One-line or Optical synchronisation system (Channel 0) ON>OFF 6.6
OFF>ON 48.7*2
All blocked>ON 63.1*3
Optical synchronisation system (Channel A or B) ON>OFF 6.9
OFF>ON 49.1*2
All blocked>ON 64.2*3
Detection mode Turns on when no interruptions are present in the detection zone
Synchronisation between the transmitter and receiver Optical synchronisation or Wire synchronisation (Determined by wiring)
Light interference prevention function Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically
Control output (OSSD output) Output 2 transistor outputs. (PNP or NPN is determined by the cable type)
Max. load current 500 mA*4
Residual voltage (during ON) Max. 2.5 V (with a cable length of 5 m)
OFF state voltage Max. 2.0 V (with a cable length of 5 m)
Leakage current Max. 200 µA
Max. capacitive load 2.2 µF
Load wiring resistance Max. 2.5 ?
Supplemental output (Non-safety-related output) AUX transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m)
Error output
Muting lamp output Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected.
External input When using a PNP output cable EDM input Wait input Reset input Muting input 1, 2 Override input ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
When using an NPN output cable ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
Rating Power voltage 24 VDC ±20%, ripple (P-P) 10% or less, Class 2
Power supply Current consumption (Max.) (mA) Transmitter 43
Receiver 66
Protection circuit Reverse current protection, short-circuit protection for each output, surge protection for each output
Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1
EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA
Safety IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998
Environmental resistance Enclosure rating IP65/IP67 (IEC60529)
Overvoltage category II
Ambient light Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less
Operating ambient temperature -10 to +55 °C (No freezing)
Storage temperature -25 to +60 °C (No freezing)
Operating relative humidity 15 to 85 % RH (No condensation)
Storage relative humidity 15 to 95 % RH
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Main unit case Aluminium
Upper case/lower case Nylon (GF 30%)
Front cover Polycarbonate, SUS304
Weight Transmitter 210 g
Receiver
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m. *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms. *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation, the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then determines the clear or blocked. *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA.