Mounting bracket SZ-V32NX Keyence
Mounting bracket SZ-V32NX Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence SZ-V32NX

Manufacturer

Keyence

Country

Japan

Name

SZ-V32NX

Type

Mounting bracket

Description

1 Nr. Keyence-Scanner SZ-V32NX Keyence

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications SZ-V32NX

If you want to buy Keyence SZ-V32NX , as well as order other industrial equipment and replacement parts for its mend, please call FAMAGA .

We have been supplying Keyence units all around the UK and anywhere in the world for over 10 years. All apparatus and parts are provided with appropriate quality certificates, together with a guarantee from the official creator of products Keyence.

Thanks to the direct deliveries from global European manufacturers and a minimal trade margin, we recommend our customers the most fair costs for all products presented in our catalogue. If necessary, our professional managers will help you select industrial equipment that will fully meet the needs of the manufacturing process. More than 4,000 customers have already appreciated the high quality of the units we supply and the dedication of the FAMAGA team members.

To illuminate the cost of Keyence SZ-V32NX and shipment time, you can complete a special filling form on our website, send a list of essential apparatus by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide adequate distribution times to any city in Great Britain and any country in the world.

Features SZ-V32NX

Network type with camera function
Model SZ-V32NX*1
Type Network Type
Detection capability Minimum detectable object size Diameter: 20, 30, 40, 50, 70, 150 mm (depends on the setting), Reflectance: 1.8% min., Speed: 1.6 m/s max.*2
Detectable angle 190° (-5° to 185°)
Response time (ON to OFF) Standard Mode Scan Cycle A 160 ms (2 scans) to 1280 ms (16 scans)*3*4
Scan Cycle B 168 ms (2 scans) to 1344 ms (16 scans)*3*4
Scan Cycle C 176 ms (2 scans) to 1408 ms (16 scans)*3*4
High Speed Mode Scan Cycle A 80 ms (2 scans) to 640 ms (16 scans)*3*4
Scan Cycle B 84 ms (2 scans) to 672 ms (16 scans)*3*4
Scan Cycle C 88 ms (2 scans) to 704 ms (16 scans)*3*4
Response time (OFF to ON) Response time of ON to OFF + 150 ms
Protection zone Minimum detectable object size: 70 / 150 mm Standard Mode: 8.4 m / High Speed Mode: 5.7 m
Minimum detectable object size: 50 mm Standard Mode: 5.6 m / High Speed Mode: 3.8 m
Minimum detectable object size: 40 mm Standard Mode: 4.3 m / High Speed Mode: 2.9 m
Minimum detectable object size: 30 mm Standard Mode: 2.9 m / High Speed Mode: 2.0 m
Minimum detectable object size: 20 mm Standard Mode: 1.6 m / High Speed Mode: 1.1 m
Warning zone Minimum detectable object size: 70 / 150 mm Standard Mode: 26 m / High Speed Mode: 23 m*5
Minimum detectable object size: 50 mm Standard Mode: 25 m / High Speed Mode: 21 m*5
Minimum detectable object size: 40 mm Standard Mode: 24 m / High Speed Mode: 20 m*5
Minimum detectable object size: 30 mm Standard Mode: 23 m / High Speed Mode: 18 m*5
Minimum detectable object size: 20 mm Standard Mode: 21 m / High Speed Mode: 15 m*5
Additional safety distance 100 mm*6
Maximum measurement distance 60 m*7
Maximum number of banks Max. 32 banks*8
Multiple scanner heads Max. 3
Camera Monitor area: over 190° (-5° to 185°)*9
Display QVGA 2.2 inch colour LCD
Light source Type, wavelength Infrared laser diode, 905 nm
Laser class IEC Class 1 IEC / EN 60825-1
FDA Class 1 FDA 21 CFR 1040.10, 1040.11 (Laser Notice No.50)*10
JIS Class 1 JIS C6802
Control output (OSSD output) Output type PNP or NPN transistor output (settings configurable with SZ-V Configurator)
Number of outputs 2 outputs
Max. load current 500 mA*11
Residual voltage Max. 2.5 V (with a cable length of 5 m)
OFF-state voltage Max. 2.0 V (with a cable length of 5 m)
Leakage current Max. 1 mA*12
Max. capacitive load 2.2 µF (with a load resistance of 100 ?)
Load wiring resistance Max. 2.5 ?
Input (safety-related) PNP ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (EDM input: Approx. 10 mA)
NPN ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM)
Non safety-related output (AUX output) Output type Transistor output (PNP or NPN, settings configurable with SZ-V Configurator)
Number of outputs 4 outputs
Max. load current 50 mA
Residual voltage (during ON) Max. 2.5 V (with a cable length of 5 m)
Muting lamp Connectable to incandescent lamp (24 VDC, 1 to 5.5 W) and LED lamp (load current: 10 to 230 mA)
Interface USB USB 2.0
Ethernet Standard IEEE802.3u (100BASE-TX)
Transmission rate 100 Mbps
Cable Category5 or higher STP (Shielded Twisted Pair) or UTP (Unshielded Twisted Pair) cable
Connector RJ45 (IP65 connector) 2 ports
Networking/data output PROFIsafe, PROFINET, EtherNet/IPTM, UDP
Cable length Power cable 30 m or less*13
Connection cable 20 m or less each*14
Ethernet cable 100 m or less*15
Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE)
EMI EN55011 Class A, FCC Part15B Class A, ICES-003 Class A
Safety IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE), IEC61496-3, EN61496-3 (Type3 AOPDDR), IEC61508, EN61508, IEC62061, EN62061 (SIL2/SILCL2), EN ISO13849-1:2015 (PLd, Category3), IEC61784-3-3, UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8
Rating Power consumption 13.4 W (without load), 50.8 W (with load)*16
Power voltage When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less When using a battery: 24 VDC +20 % /-30 %
Environmental resistance Enclosure rating IP65 (IEC60529)
Ambient light Incandescent lamp: 1,500 lux or less*17
Operating ambient temperature -10 to +50 °C (No freezing)
Storage temperature -25 to +60 °C (No freezing)
Operating relative humidity 35 to 85 % RH (No condensation)
Storage relative humidity 35 to 95 % RH
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Scanner head Main unit case Magnesium
Window Polycarbonate, PEI
Indicator part Aluminum, PES*9
Display unit case Magnesium, PPS, Polycarbonate
System memory Aluminum, PPE
Weight Approx. 2,300 g
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). *2 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting. *3 The response time, protection zone, and warning zone are affected by the operation mode. *4 When PROFIsafe is used with the SZ-V32N, 6 ms is added to the response time. *5 20% or more reflectance is necessary for the minimum detectable object in the warning zone. *6 If there is a highly reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance. *7 Even when using the network data output, the maximum measured output distance is 60 m. *8 When PROFIsafe is used with the SZ-V32N, maximum number of banks is 16. *9 Only applicable for the type with a camera. *10 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *11 The load current calculation of the OSSD output and AUX output is 1.2 A or less when using one scanner head, 0.8 A or less when using two scanner heads, and 0.3 A or less when using three scanner heads. *12 Includes when the power is OFF. *13 10 m or less when supplying power from a battery. *14 When supplying power from a battery, the length of each connection cable should be 10 m or less when using two scanner heads, and 5 m or less when using three scanner heads. *15 Distance between SZ-V and Ethernet switch *16 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation. *17 An ambient light source should not be located within ±5° of the detection plane.