Description

E/P Druckregelventil, Serie ED02 ED02-000-100-010-1M12A BauartSitzventil ZertifikateCE-Konformitätserklärung Betriebsdruck min.0.5 bar Betriebsdruck max.12 bar Umgebungstemperatur min.0 °C Umgebungstemperatur max.50 °C Druckluftanschluss Eingang1/8 NPT, G 1/8 Druckluftanschluss Ausgang1/8 NPT, G 1/8 MediumDruckluft Nenndurchfluss Qn120 l/min Ansteuerunganalog Betriebsspannung DC24 V Hysterese< 0,05 bar Einbaulage±α = 0 ... 90° ±β = 0 ... 90° Zulässige Oberwelligkeit5% Stromaufnahme max.300 mA SchutzartIP65 Elektrischer Anschlussüber Signalanschluss SignalanschlussEingang und Ausgang SignalanschlussStecker SignalanschlussM12 Signalanschluss5-polig Istwertausgang0 ... 10 V Sollwerteingang0 ... 10 V Druckregelbereich min.0 bar

Stock availability:

On request

472 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications R414002413 (ED02-000-100-010-1M12A) AVENTICS - E/P Druckregelventil, Serie ED02 R414002413

If you want to gain Aventics (brand of Emerson) R414002413 (ED02-000-100-010-1M12A) AVENTICS - E/P Druckregelventil, Serie ED02 R414002413, in addition order other industrial equipment and replacement parts for its repair, please connect FAMAGA .

We have been delivering Aventics (brand of Emerson) goods all over Britain and anywhere in the planet for over 10 years. All machinery and replacements are provided with appropriate quality certificates, along with a guarantee from the official manufacturer of products Aventics (brand of Emerson).

Thanks to the upfront deliveries from prominent European manufacturers and a nominal trade margin, we offer our customers the most affordable prices for all products exhibited in our catalogue. If necessary, our qualified specialists will help you choose industrial equipment that will fully meet the necessities of the production process. More than 4,000 buyers have already praised the high quality of the elements we bring and the professionalism of the FAMAGA staff.

To clarify the price of Aventics (brand of Emerson) R414002413 (ED02-000-100-010-1M12A) AVENTICS - E/P Druckregelventil, Serie ED02 R414002413 and delivery terms, you can complete a special order form on our website, send a list of required equipment by E-mail or call to the indicated phone numbers. We will be able to make the best sales offer for you and provide adequate supply times to any city in Great Britain and any country in the world.

Features R414002413 (ED02-000-100-010-1M12A) AVENTICS - E/P Druckregelventil, Serie ED02 R414002413

Version Poppet valve
Mounting orientation ±α = 0 ... 90° ±β = 0 ... 90°
Certificates CE declaration of conformity
Working pressure max See table
Ambient temperature min./max. 0 ... 50 °C
Medium temperature min./max. 0 ... 50 °C
Compressed air connection input G 1/8 1/8 NPT
Compressed air connection output G 1/8, 1/8 NPT
Medium Compressed air
Max. particle size 50 µm
Oil content of compressed air 1 mg/m³
Nominal flow Qn 120 l/min
Control Analog
DC operating voltage 24 V
Voltage tolerance DC -20% / +20%
Permissible ripple 5%
Max. power consumption 300 mA
Protection class IP65
Weight 0,32 kg
Nominal flow Qn with working pressure 7 bar , with secondary pressure 6 bar and Δp = 0.2 bar
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre).
With oil-free, dry air, other installation positions are possible on request. ED02 series valves can be assembled into blocks using tie rods (see accessories). The protection class is only ensured when the plug is mounted properly. For detailed information, see operating instructions. The compressed air connection threads fit both G 1/8 and 1/8 NPTF.
Material
Housing Die-cast aluminum Steel
Seals Hydrogenated acrylonitrile butadiene rubber