We are not the manufacturer, authorised distributor or authorised representative of the Aventics (brand of Emerson) brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Aventics (brand of Emerson)
Country
Germany
Part number
R422102676
Description
Standardization | ISO 5599-1 |
Frame size | ISO 1 |
Actuating control | single solenoid |
Return type | With spring return |
Switching principle | 5/2 |
Version | Spool valve, positive overlapping |
Housing | Polyamide,Aluminum |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Port size | M12 |
Type | Plug |
Nominal flow Qn | 1060 l/min |
Compressed air connection input | Base plate DIN ISO 5599 size 1 |
Compressed air connection output | Base plate DIN ISO 5599 size 1 |
DC operating voltage | 24 V |
Stock availability:
On request
If you want to get Aventics (brand of Emerson) R422102676, additionally require other industrial equipment and constituent parts for its fix, please approach FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Congo, Burundi, Burma, Bosnia and Herzegovina, Fiji, Spain, Tunisia, Algeria, Guyana, Belize, Australia, Montenegro, The Bahamas, South Korea, Senegal, Gambia, Vietnam, Kiribati, Monaco, Pakistan, Burkina Faso, Bolivia, Russia, Philippines, Mozambique, Kazakhstan, Denmark, Japan, China, Venezuela, Sri Lanka, Comoros, Belarus, Estonia, United Arab Emirates, The Gambia, Ukraine, Libya, Mauritius, Jamaica, Ecuador, Moldova, Malaysia.
We have been supplying Aventics (brand of Emerson) goods all around the UK and anywhere in the globe for over 9 years. All machinery and materials are provided with appropriate quality certificates, along with a guarantee from the official creator of products Aventics (brand of Emerson).
Thanks to the upfront deliveries from global European manufacturers and a minimal trade margin, we offer our customers the most fair costs for all products exposed in our catalogue. If necessary, our proficient consultants will help you pick industrial instruments that will fully meet the necessities of the mode of operation. More than 4,000 customers have already comprehended the high quality of the products we bring and the dedication of the FAMAGA team members.
To clear up the expense of Aventics (brand of Emerson) R422102676 and shipment time, you can complete a special filling form on our website, dispatch a list of necessary machinery by E-mail or call to the specified phone numbers. We will be able to compose the best sales offer for you and prepare prompt distribution times to any place in Great Britain and any country in the world.
Version | Spool valve, positive overlapping |
Sealing principle | Soft sealing |
Blocking principle | Single base plate principle |
Connection type | Plate connection |
Standards | ISO 5599-1, ISO 1 |
Working pressure min./max. | See table |
Control pressure min./max. | 3 ... 10 bar |
Ambient temperature min./max. | 0 ... 50 °C |
Medium temperature min./max. | 0 ... 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 ... 0,01 mg/m³ |
Nominal flow Qn | 1060 l/min |
Protection class with connection | IP65 |
Compatibility index | 15 |
Duty cycle | 100 % |
Switch-on time max. | 18 ms |
Switch-off time max. | 40 ms |
Version sensor | electronic PNP, with LED |
Sensor connection | Plug, M8, 3-pin, with knurled screw |
Operating voltage sensor DC min./max. | 10 ... 30 V DC |
Voltage drop sensor U at Imax | ≤ 2,5 V |
Vibration resistance sensor | 10 - 55 Hz, 1 mm |
Shock resistance sensor | 30 g / 11 ms |
Cable length sensor | 0,3 m |
Protection class sensor acc. to DIN EN 61140 | Class III |
Mounting screw | M5 with hexagon socket |
Weight | See table |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
When the valve is not actuated, the sensor sends a signal through pin 4 of the sensor connection. When the valve is actuated, the sensor does not send a signal through pin 4 of the sensor connection. The valve with position detection is possible to be used in categories 3 and 4 according to ISO 13849 in order to reach a Performance Level (PL) of the control system up to PL = e. On its own, the valve with position detection is not a safety component and is not a complete safety solution. It is designed to increase the diagnostic coverage (DC) of the control system. For use in categories 3 to 4, additional requirements of DIN EN ISO 13849-1:2008-12 (e.g. CCF, DC, PLr, software, systematic errors) are taken into consideration by the user. |
Housing | Polyamide Aluminum |
Seals | Acrylonitrile butadiene rubber |