We are not the manufacturer, authorised distributor or authorised representative of the Aventics (brand of Emerson) brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Aventics (brand of Emerson)
Country
Germany
Part number
R422003653
Description
Standardization | ISO 5599-1 |
Frame size | ISO 2 |
Actuating control | single solenoid |
Return type | With differential piston |
Switching principle | 5/2 |
Version | Spool valve, positive overlapping |
Housing | Polyamide,Aluminum |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Nominal flow Qn | 2500 l/min |
Compressed air connection input | Base plate DIN ISO 5599 size 2 |
Compressed air connection output | Base plate DIN ISO 5599 size 2 |
Stock availability:
On request
If you want to gain Aventics (brand of Emerson) R422003653, in addition require other industrial equipment and constituent parts for its adjust, please approach FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Andorra, Syria, Belgium, Bahamas, Georgia, Gambia, Switzerland, Burma, Dominica, Argentina, Malawi, Ghana, Turkmenistan, Uzbekistan, Comoros, Guyana, Israel, Venezuela, Madagascar, Togo, Guinea, Palestine, Ukraine, Zambia, Azerbaijan, Mauritania, Jamaica, Barbados, Kuwait, South Korea, India, Thailand, Bosnia and Herzegovina, Oman, Cameroon, Afghanistan, Dominican Republic, Sierra Leone, United Arab Emirates, The Bahamas, Sweden.
We have been delivering Aventics (brand of Emerson) items all over Britain and anywhere in the planet for over 11 years. All apparatus and materials are provided with appropriate quality certificates, as well as a guarantee from the official manufacturer of products Aventics (brand of Emerson).
Thanks to the upfront deliveries from leading European manufacturers and a nominal trade margin, we recommend our customers the most fair costs for all products exposed in our catalogue. If necessary, our proficient consultants will help you pick industrial equipment that will fully meet the necessities of the production process. More than 4,000 buyers have already praised the high quality of the elements we transport and the competence of the FAMAGA team members.
To clarify the charge of Aventics (brand of Emerson) R422003653 and delivery terms, you can complete a special filling form on our website, dispatch a list of desirable machinery by E-mail or call to the quoted phone numbers. We will be able to make the best sales offer for you and provide adequate supply times to any urban place in Britain and any country in the earth.
Version | Spool valve, positive overlapping |
Sealing principle | Soft sealing |
Blocking principle | Single base plate principle |
Connection type | Plate connection |
Standards | ISO 5599-1, ISO 2 |
Working pressure min./max. | See table |
Control pressure min./max. | 3 ... 10 bar |
Ambient temperature min./max. | 0 ... 50 °C |
Medium temperature min./max. | 0 ... 60 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 ... 0,01 mg/m³ |
Nominal flow Qn | 2500 l/min |
Protection class with connection | IP65 |
Compatibility index | 15 |
Duty cycle | 100 % |
Switch-on time max. | 20 ms |
Switch-off time max. | 50 ms |
Version sensor | electronic PNP, with LED |
Sensor connection | Plug, M8, 3-pin, with knurled screw |
Operating voltage sensor DC min./max. | 10 ... 30 V DC |
Voltage drop sensor U at Imax | ≤ 2,5 V |
Vibration resistance sensor | 10 - 55 Hz, 1 mm |
Shock resistance sensor | 30 g / 11 ms |
Cable length sensor | 0,3 m |
Protection class sensor acc. to DIN EN 61140 | Class III |
Mounting screw | M6 with hexagon socket |
Weight | See table |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
When the valve is not actuated, the sensor sends a signal through pin 4 of the sensor connection. When the valve is actuated, the sensor does not send a signal through pin 4 of the sensor connection. The valve with position detection is possible to be used in categories 3 and 4 according to ISO 13849 in order to reach a Performance Level (PL) of the control system up to PL = e. On its own, the valve with position detection is not a safety component and is not a complete safety solution. It is designed to increase the diagnostic coverage (DC) of the control system. For use in categories 3 to 4, additional requirements of DIN EN ISO 13849-1:2008-12 (e.g. CCF, DC, PLr, software, systematic errors) are taken into consideration by the user. |
Housing | Polyamide Aluminum |
Seals | Acrylonitrile butadiene rubber |